45
MS 460, MS 460 C
The ignition module accommodates
all the components required to
control ignition timing. There are
two electrical connections on the
coil body:
:
High voltage output (1) for
ignition lead
VA
176RA149
1
2
:
Connector tag (2) for short
circuit wire
Testing in the workshop is limited to
a spark test.
A new ignition module must be
installed if no ignition spark is
obtained (after checking that wiring
and stop switch are in good
condition).
Ignition timing is fixed and cannot
be adjusted during repair or
servicing work
Since there is no mechanical wear
in these systems, ignition timing
cannot get out of adjustment as a
result of wear.
– Remove the shroud,
b
6.4
– Remove the fan housing with
rewind starter,
b
8.2
:
Pull the short circuit wire (1) off
the connector tag on the ignition
module and out of the wire
retainer (2).
VA
176RA152
1
2
:
Take out the screws (arrows).
– Remove the ignition module.
VA
176RA153
7.1
Ignition Module
7.1.1
Ignition Timing
7.1.2
Removing and Installing