Operation & Service Manual (VA)
72
ST1175
Error
code
Code/label
Possible cause
Solution
36
Output power
supply fault
Defective power
supply to outputs.
Set the main switch(es) to
OFF.
Check and replace fuse F2
(3.15A) if required. Also
check the thermal relay and
reset it if required. Turn on
the control box again using
the standard procedure. If
the fault occurs again,
contact the technical service.
37
Short circuit on
PCB
Short circuit on the
PCB.
Allow damp box to dry.
Replace PCB if the fault
persists.
82
EPROM read
fault
Turn OFF and ON on the
main switch(s) and press the
[SELECT] button to ensure
the system can be used
again. Replace the PCB if
required.
83
EPROM write
fault
91
Watchdog fault
93
General CAN
error
94
95
CAN timeout
8.4
Faults
The following troubleshooting guide can be used to help localize faults. If in doubt,
the user should contact the technical service.
In the event of malfunctions other than those described here, always consult the
technical service.
Summary of Contents for ST1175
Page 1: ... 2014 Stertil B V 32808980 A VA 32808980 A Operation Service Manual ST1175 Mobile Column Lift ...
Page 80: ...Operation Service Manual VA 80 ST1175 10 1 Main components ...
Page 84: ...Operation Service Manual VA 84 ST1175 10 2 Hydraulic unit ...
Page 86: ...Operation Service Manual VA 86 ST1175 10 3 Hydraulic cylinder ...
Page 88: ...Operation Service Manual VA 88 ST1175 10 4 Control box primary ...
Page 90: ...Operation Service Manual VA 90 ST1175 10 5 Control box secondary ...
Page 93: ...Operation Service Manual VA 93 ST1175 10 7 Pallet jack mechanism ...
Page 95: ...Operation Service Manual VA 95 ST1175 10 8 Label locations ...
Page 97: ...Operation Service Manual VA 97 ST1175 11 LIST OF PARTS VARIANTS AND OPTIONS ...
Page 103: ...Operation Service Manual VA 103 ST1175 12 5 Dimensional drawing ...
Page 107: ......