1 (ON)
This will activate the power supply to the column lift(s).
Follow the next described procedure to start the vehicle lift:
1. Turn the main switch to position [1] and press [SELECT] once.
This switches on the main and control circuit power, and the vehicle lift is ready for
use.
A control box on a slave column does not has a main switch.
6.4.3
Raising
To raise the column lifts, press the [UP] button. There is an arrow pointing up
beside this button.
6.4.4
Lowering
Activate the [UNLOCK] button simultaneously with the [DOWN] button to lower the
column lifts. There is an arrow pointing down next to the [DOWN] button.
If the foot protection has been enabled, the lowering action will be interrupted at
approx. 12" above the floor. The column will be lowered further, with an acoustic
signal, when the [UNLOCK] and the [DOWN] are pressed again simultaneously.
This option can be set by a technical service department recognized by Stertil.
If problem situations arise during raising or lowering, release the control buttons or
press the emergency stop.
WARNING
Summary of Contents for ST1175
Page 1: ... 2014 Stertil B V 32808980 A VA 32808980 A Operation Service Manual ST1175 Mobile Column Lift ...
Page 80: ...Operation Service Manual VA 80 ST1175 10 1 Main components ...
Page 84: ...Operation Service Manual VA 84 ST1175 10 2 Hydraulic unit ...
Page 86: ...Operation Service Manual VA 86 ST1175 10 3 Hydraulic cylinder ...
Page 88: ...Operation Service Manual VA 88 ST1175 10 4 Control box primary ...
Page 90: ...Operation Service Manual VA 90 ST1175 10 5 Control box secondary ...
Page 93: ...Operation Service Manual VA 93 ST1175 10 7 Pallet jack mechanism ...
Page 95: ...Operation Service Manual VA 95 ST1175 10 8 Label locations ...
Page 97: ...Operation Service Manual VA 97 ST1175 11 LIST OF PARTS VARIANTS AND OPTIONS ...
Page 103: ...Operation Service Manual VA 103 ST1175 12 5 Dimensional drawing ...
Page 107: ......