Operation & Service Manual (VA)
56
ST1175
Maintenance
tasks
Description
Monthly
Per year
(technical
service)
Every 2
years
(technical
service)
Safety lock
Disassemble,
clean and replace
(if necessary),
and adjust; see
section Checking
the safety locking
feature.
x
7.6.2
Hydraulic oil
Replace the hydraulic oil in the tank approximately once every 2 years.
This oil change must take place as scheduled, even when the column lift is not
being used continuously.
When changing the hydraulic oil, proceed as follows:
1. Fully lower the column lifts and drain off the oil.
2. Fill the tank with hydraulic oil filtered at maximum 4 microns.
Hydraulic oil type
Oil type
Oil name
Standard
Unil HVC SX 15
Alternative
Mobil DTE 10
Excel 15
Biological
degradable
Panolin SYNTH
15 (on customers
request)
The different types of oils should not be mixed.
Summary of Contents for ST1175
Page 1: ... 2014 Stertil B V 32808980 A VA 32808980 A Operation Service Manual ST1175 Mobile Column Lift ...
Page 80: ...Operation Service Manual VA 80 ST1175 10 1 Main components ...
Page 84: ...Operation Service Manual VA 84 ST1175 10 2 Hydraulic unit ...
Page 86: ...Operation Service Manual VA 86 ST1175 10 3 Hydraulic cylinder ...
Page 88: ...Operation Service Manual VA 88 ST1175 10 4 Control box primary ...
Page 90: ...Operation Service Manual VA 90 ST1175 10 5 Control box secondary ...
Page 93: ...Operation Service Manual VA 93 ST1175 10 7 Pallet jack mechanism ...
Page 95: ...Operation Service Manual VA 95 ST1175 10 8 Label locations ...
Page 97: ...Operation Service Manual VA 97 ST1175 11 LIST OF PARTS VARIANTS AND OPTIONS ...
Page 103: ...Operation Service Manual VA 103 ST1175 12 5 Dimensional drawing ...
Page 107: ......