Maintenance Manual STEMME S10-VT
Date of Issue: Dec. 19, 1997
Page: 5-4
Amendment No.: 23
Date: Jan. 29, 2015
A4011121_B23.doc
Doc. No. A40-11-121
(7) Inspect the plastic fuel check valves when they reach 5 years in service as specified below in section
5.3.3. Replace the plastic fuel check valves when they reach 10 years in service.
Steel fuel check valves have no specific TBR and are to be replaced only on condition.
(8) Seat belts must be inspected and, if needed, be repaired or replaced pursuant to applicable national
regulations.
(9) An installed ELT (optional) and its battery must be tested according to applicable national regulations.
(10)
The L’Hotelier connections wear with use and their security
is critical to safe flight. STEMME
recommends that the owner and operator inspect these connectors per L’Hotellier
Instructions for the
Maintenance L'Hotellier Ball and Swivel Joints, Ref. IMA10.01, in the latest approved revision.
This
technical data may be obtained from L'Hotelier S.A., 93 Avenue Charles De Gaulle, 92270 Bois
Colombes, France.
See Appendix A, section A40-11-
122 for L’Hotelier’s specified inspection procedure and tolerances.
(11) Refer to instructions prescribed by the component manufacturers
—
airworthiness limitations section of
the manufacturer documentation, applicable maintenance manual, Service Bulletins, etc.
—
for those
manufacturer’s permissible service life limits and overhaul recommendations of components.