cracking,
obstruction of drainage or vent holes,
deformation,
signs of overheating, fluid saturation and any other apparent damage.
Metal Parts:
Securely installed,
condition of finish,
cleanliness,
distortion,
fatigue cracks,
welding cracks,
corrosion, and
any other apparent damage.
Fuel, Air Oil, Coolant and Hydraulic Fluid Lines and Hoses:
Leaks,
cracks,
dents,
kinks,
loss of flexibility,
sign of deterioration,
obstruction,
chafing,
improper bend radius,
cleanliness,
securely installed, and
any other apparent damage
Electrical Wiring:
Cleanliness,
loose, corroded or broken terminals,
chafed, broken or worn insulation,
wires and wire bundles securely installed,
signs of heat deterioration, and
any other apparent damage.
Bolts and Nuts
:
Fretting,
wear,
damage,
stretch,
cross
–
threading,
proper torque,
corrosion, and
locking or safety wiring.
Filters and Screens:
Filters and screens shall be removed, cleaned, and inspected for contamination and
they shall be replaced as appropriate or required.
Fuel filters encased in metal should be replaced at the recommended intervals.
Wet Fuel Areas:
Cleanliness,
leaks,
bacterial growth,
corrosion,
delamination,
separation of bond,
deterioration of fuel tank lining,
and structural fatigue