STEIN300_Radius Circuit_06_GB.doc / 01.2020
15
Fig. 5-2:
Example:
Radius circuit 180°
Radius circuit 90°
1
Double column stand
2
Single column stand
3
Adjustable bases
180° radius circuit: Remove the double column stand from the radius circuit
90° radius circuit: Remove the two stands from the radius circuit.
Installation
Place the radius circuit onto the protective mat so that the underneath of the radius
circuit is on top.
180° radius circuit: Attach the double column stand to the radius circuit.
90° radius circuit: Attach the two stands to the radius circuit.
Tighten the stand connecting screws.
Fig. 5-3:
Adjustable base adjust-
ment
1
Locknut
2
Adjustable base
Adjust the stand bases to their lowest level.
Erect the module into a vertical position with the aid of suitable lifting gear or
through help from assistants.
1
3
2
3
1
2