STEIN300_Radius Circuit_06_GB.doc / 01.2020
11
4
Technical description
4.1
Scope of delivery
Radius circuits 90° and 180° are delivered:
•
With drive motor and
•
Entry and exit transfers (fitted to the BE).
i
The following accessories are not part of the normal scope of delivery:
•
Control unit (STEIN Automation option)
•
Safety cover over the drive rollers (STEIN Automation optional extra)
i
Pile-up separation is achieved by the installation of P-accessories (STEIN Automation
optional extra).
Fig. 4-1:
Basic configurations:
1
E-basic configuration
with 180° radius cir-
cuits
2
F-basic configuration
with 90° radius cir-
cuits
E-basic configurations
(WTS- Alpha) are equipped with 180° radius circuits.
F-basic configurations
are equipped with 90° radius circuits.
i
The distance between the belt elements in the case of the E-basic configuration (inside
width) is 106 mm.
Radius circuit 90°
The 90° radius circuit changes the transport direction of the WT through 90°. The 90°
radius circuit is fitted to the guide profiles of the belt element.
Radius circuit 180°
The 180° radius circuit guides the WT onto a parallel-running section.
Procedure:
The WT is transported up to the entry point of the radius circuit by the two transport
belts of the belt element. Then the WT direction is changed by 90° or 180° respectively
through it being transported on over the roller section of the radius circuit. At the exit
point of the radius circuit, a belt element takes over the onward transport of the WT.
i
Standard WTS sizes: 160x160, 240x240, 320x320, 400x400 mm
Other sizes on request.
1
2