 Accessories

Accessories are identified by the transmitter 
according to the internal wiring of the plug. 
For this reason it is important to use only 
accessories which are approved for use  
with the RD5000WLT. For more information 
please contact Radiodetection or visit:  

www.radiodetection.com

No accessory

When no accessories are plugged in default 
operation is induction mode, outputting the 
transmitter signal via the internal induction 
coil.

Direct connect leads (output)

When this accessory is plugged into the 
accessory socket, the transmitter output 
switches from internal induction to direct 
connect. The locate signal will appear as an 
alternating voltage on the direct connect 
clips.

Transmitter signal clamp

When this accessory is plugged into the 
accessory socket, the transmitter output 
switches to signal clamp mode. The locate 
signal will appear on the clamp and be 
transferred by induction to the selected  
target line.

Battery charger (input)

When this accessory is plugged into the 
accessory socket, the transmitter will 
switch off all locate signals and connect the 
charging circuit to the Li-Ion battery.

Installation/Operation

The RD5000WLT transmitter is battery 
powered; it does not have a protective earth 
connection, and cannot be powered by an 
external power supply.
The internal lithium-ion battery can be 
charged using the supplied charger. The 
transmitter will not transmit a locate signal 
while charging.
The RD5000WLT transmitter is controlled 
by a single button – operation is explained in 
the user guide.

When using direct connection, hazardous 
voltages may be present on the croc clips of 
the direct connect lead and these voltages 
may appear on other accessible conductors. 
Therefore it is essential to be aware of the 
hazards and protect against them.
Take appropriate precautions to minimize  
the risks:
•  Check that the target conductor is not 

live before making connections.

•  Make connections first, before powering  

up the transmitter.

•  Protect the connections (e.g. to the earth 

spike if used or other connection points) 
from public access.

•  Warn other workers on site that 

conductors may be hazardous.

•  Keep direct connect voltage as low as 

possible for the survey.

•  Keep the connection time as short as 

possible.

Maintenance

Regularly check the condition of all 
accessories and the casing of the 
RD5000WLT transmitter. Pay particular 
attention to the condition of the Direct 
Connect accessory leads as these can 
operate at voltages deemed to be hazardous 
when wet. Specifically, check that insulation  
is not broken and replace any worn parts.
The RD5000WLT transmitter has no user 
serviceable parts other than replacement 
of the fuse or provision of auxiliary D-cell 
batteries.
The fuse must be replaced with an equivalent 
20mm x 5mm 2A Time Delay Fuse.
The 4 × D-cell batteries used must all be of 
the same type. Renew them all at the same 
time.
If the RD5000WLT transmitter is dirty, 
wipe it down with a damp cloth and mild 
detergent. Avoid the use of solvents or other 
strong chemicals.

Locating pipes and cables  
with the RD5000

Applying the signal using direct connection

In direct connection, you connect the transmitter output directly to the pipe or 
to the conductor of the cable you wish to survey. The transmitter will then apply 
an active frequency signal, which you can locate using the locator. This is the 
preferred method for providing the strongest signal on a particular line and is 
particularly useful for long distance tracing.
Connecting the transmitter to a pipe or cable in direct connect mode, requires the 
use of a direct connection lead, which is connected to the accessory socket of 
the transmitter. The red lead is connected to the pipe or cable and the black lead 
connected to an earth stake to complete the electrical circuit. 

 WARNING! In Direct connect mode, output voltage can be up to 30V RMS 

which is POTENTIALLY LETHAL in wet conditions.

 WARNING! Direct connection to live wires is POTENTIALLY LETHAL.  

Direct connections should be made by competent personnel only. DO NOT 
connect to live conductors!

Applying the signal using induction

When it is not possible to use the transmitter in direct connection mode, the 
transmitter can be placed on the ground over or near the survey area with the 
arrow on the transmitter in line with the target line. The transmitter will then 
induce the signal indiscriminately to any nearby buried metallic conductors. When 
using the transmitter in induction mode it should be noted that the signal from the 
transmitter will transmit not only below the transmitter but above the transmitter 
and it is recommended that the locator should not be used within a minimum of 15 
meters (50 feet) from the transmitter.

Applying the signal using a transmitter signal clamp

When it is not possible to use either direct connection or induction methods, a 
transmitter signal clamp, can be used to induce the signal onto the target line. 
Connect the clamp to the accessory socket of the transmitter and fit the clamp 
around the target line. The clamp is particularly useful with insulated live cables as 
this removes the need to disable the power and break into the line.

Summary of Contents for RADIODETECTION RD5000 WL

Page 1: ...RD5000 WL User guide Guide d utilisation 90 UG089INT 04...

Page 2: ...3 ENGLISH 4 FRAN AIS 24...

Page 3: ...ftware download page on the Radiodetection website After 12 months from purchase the registered user will be notified and offered the chance to validate the calibration of the RD5000 locator using eCA...

Page 4: ...etween Guidance Mode and Signal Strength Mode Locator display icons 7 Target position indicator Indicates position of locator relative to target line 8 Signal strength Numerical indication of signal s...

Page 5: ...Nominal power output 1W in Direct Connect mode Batteries Internal rechargeable battery pack 4 x D Cells LR 20 Warranty 12 months 36 months Compliance FCC Canada 310 RoHS WEEE CE Weight 1 6kg 3 5lbs in...

Page 6: ...o be hazardous when wet Specifically check that insulation is not broken and replace any worn parts The RD5000WLT transmitter has no user serviceable parts other than replacement of the fuse or provis...

Page 7: ...ocator is now ready to use Note When the locator is positioned at a specific distance from the target line the depth and current values will automatically display although these values will not be acc...

Page 8: ...ithin Centros Manager and to download the latest software you must register for extended warranty see page 5 for details Once registered you will receive an email when new versions of software are ava...

Page 9: ...on the date the eCAL was carried out to display the certificate of validation 7 Once an eCAL has been carried out the validation certificate may be viewed or printed at any time without the need to lo...

Page 10: ...charge rechargeable batteries for their recommended charge time before first use If at any time the rechargeable batteries do not last as long as expected discharge them fully and then recharge for t...

Page 11: ...l be provided by Radiodetection on an exchange basis and will be either new or refurbished to be functionally equivalent to new In the event this exclusive remedy is deemed to have failed of its essen...

Page 12: ...nd certified repair houses ix Adjustments or adaptations without Radiodetection s prior written consent including i upgrading the product beyond specifications or features described in the instruction...

Page 13: ...t un courriel de notification avec un lien vers la page de t l chargement du nouveau logiciel sur le site Internet Radiodetection 12 mois apr s l achat il sera propos l utilisateur enregistr de valide...

Page 14: ...de de guidage et le mode de puissance de signal Ic nes d affichage sur le r cepteur 7 Indicateur de position de la cible indique la position du r cepteur par rapport au c ble canalisation cible 8 Nive...

Page 15: ...erie rechargeable interne 4 iltes D Cell LR 20 Garantie 12 mois 36 mois Normes FCC Canada 310 RoHS WEEE CE Poids 1 6kg 3 5lbs avec batterie rechargeable Respect de l environnement IP54 Temp rature de...

Page 16: ...if l tat des c bles de raccordements direct car ceux ci peuvent v hiculer des tensions dangereuses lorsqu ils sont mouill s Plus pr cis ment v rifiez bien que les isolents sont en bons tats et remplac...

Page 17: ...gnal du g n rateur sur la canalisation ou sur le c ble le r cepteur est maintenant pr t l emploi Remarque Quand le r cepteur est plac une distance pr cise de la canalisation cible les valeurs de profo...

Page 18: ...pour le r cepteurs RD5000 qui peut am liorer la performance la stabilit et peut inclure de nouvelles caract ristiques Centros Manager contient la derni re version du logiciel et pour t l charger le l...

Page 19: ...icat trouvez le num ro de s rie du RD5000 dans la fen tre du gestionnaire de l appareil et d veloppez les contenus D veloppez les validations eCAL et double cliquez sur la date d ex cution de l eCAL p...

Page 20: ...ment de piles alcalines utilisez uniquement la taille et le type de pile sp cifi s Ne jamais m langer des piles rechargeables et alcalines Ne jamais essayer de recharger des piles alcalines Piles rech...

Page 21: ...les marques Radiodetection Pearpoint Telespec Bicotest Riser Bond Dielectric Mark Products et Warren G V Radiodetection garantit par la pr sente que ses produits sont exempts de d fauts de mat riel et...

Page 22: ...c le produit vii Une utilisation du produit avec des accessoires des quipements p riph riques et d autres produits d un type dans un tat ou d un niveau diff rent de celui prescrit par Radiodetection v...

Page 23: ...earpoint sales us spx com www pearpoint com Radiodetection Canada 344 Edgeley Boulevard Unit 34 Concord Ontario L4K 4B7 Canada Tel 1 905 660 9995 Toll Free 1 800 665 7953 rd sales ca spx com Radiodete...

Reviews: