background image

4

5

ENGLISH

Preface

About this guide

This guide provides basic operating instructions for the RD5000

 

locator and transmitter. It also contains important safety information 
and guidelines and as such should be read in its entirety before 
attempting to operate the RD5000 locator and transmitter.

It is also highly recommended to register the RD5000 locator and transmitter 
for the free 3 year extended warranty.

Extended Warranty

Thank you for purchasing the RD5000

 locator and transmitter.

RD5000 locators and transmitters are covered by a 1 year warranty. It is highly 
recommended to register the RD5000 locator and transmitter for the free 3 year 
extended warranty.
Registration and extended warranty are free and once registered users will be 
entitled to free software updates.
To be eligible, customers must register each product within 3 months of purchase.
Upon registration customers will receive confirmation of registration by email 
and this email will include a download key, this key will be required for software 
updates to your RD5000 locator and transmitter.
When new software is released, registered users will receive a notification email 
that links to the new software download page on the Radiodetection website. 
After 12 months from purchase, the registered user will be notified and offered 
the chance to validate the calibration of the RD5000 locator using eCAL.
To register for extended warranty go to:  

www.radiodetection.com/extendedwarranty

eCAL

The RD5000 has been designed so that it does not require regular calibration. 
However, as with all safety equipment, it is recommended that a service should 
be carried out at least once a year either at Radiodetection’s service centre or 
an approved Radiodetection service centre. Alternatively eCAL

 may be used to 

validate the calibration of the RD5000 locator.

eCAL is a novel Radiodetection technique that allows the user to validate the 
original factory calibration of the RD5000 locator, providing the user with the 
confidence that the locator continues to meet its original factory calibration. 
eCAL also carries out a functional test on the locator providing the user with 
the confidence that the locator continues to provide the same performance 
as it did when it first left the factory. eCAL can be carried out on site without 
the need to return the locator to a service centre, saving time and expense. 
Each time the locator passes eCAL, the user can view or print a dated eCAL 
validation certificate. 

For a more detailed explanation of eCAL, please go to the eCAL section on 
page 16.    

Summary of Contents for RADIODETECTION RD5000 WL

Page 1: ...RD5000 WL User guide Guide d utilisation 90 UG089INT 04...

Page 2: ...3 ENGLISH 4 FRAN AIS 24...

Page 3: ...ftware download page on the Radiodetection website After 12 months from purchase the registered user will be notified and offered the chance to validate the calibration of the RD5000 locator using eCA...

Page 4: ...etween Guidance Mode and Signal Strength Mode Locator display icons 7 Target position indicator Indicates position of locator relative to target line 8 Signal strength Numerical indication of signal s...

Page 5: ...Nominal power output 1W in Direct Connect mode Batteries Internal rechargeable battery pack 4 x D Cells LR 20 Warranty 12 months 36 months Compliance FCC Canada 310 RoHS WEEE CE Weight 1 6kg 3 5lbs in...

Page 6: ...o be hazardous when wet Specifically check that insulation is not broken and replace any worn parts The RD5000WLT transmitter has no user serviceable parts other than replacement of the fuse or provis...

Page 7: ...ocator is now ready to use Note When the locator is positioned at a specific distance from the target line the depth and current values will automatically display although these values will not be acc...

Page 8: ...ithin Centros Manager and to download the latest software you must register for extended warranty see page 5 for details Once registered you will receive an email when new versions of software are ava...

Page 9: ...on the date the eCAL was carried out to display the certificate of validation 7 Once an eCAL has been carried out the validation certificate may be viewed or printed at any time without the need to lo...

Page 10: ...charge rechargeable batteries for their recommended charge time before first use If at any time the rechargeable batteries do not last as long as expected discharge them fully and then recharge for t...

Page 11: ...l be provided by Radiodetection on an exchange basis and will be either new or refurbished to be functionally equivalent to new In the event this exclusive remedy is deemed to have failed of its essen...

Page 12: ...nd certified repair houses ix Adjustments or adaptations without Radiodetection s prior written consent including i upgrading the product beyond specifications or features described in the instruction...

Page 13: ...t un courriel de notification avec un lien vers la page de t l chargement du nouveau logiciel sur le site Internet Radiodetection 12 mois apr s l achat il sera propos l utilisateur enregistr de valide...

Page 14: ...de de guidage et le mode de puissance de signal Ic nes d affichage sur le r cepteur 7 Indicateur de position de la cible indique la position du r cepteur par rapport au c ble canalisation cible 8 Nive...

Page 15: ...erie rechargeable interne 4 iltes D Cell LR 20 Garantie 12 mois 36 mois Normes FCC Canada 310 RoHS WEEE CE Poids 1 6kg 3 5lbs avec batterie rechargeable Respect de l environnement IP54 Temp rature de...

Page 16: ...if l tat des c bles de raccordements direct car ceux ci peuvent v hiculer des tensions dangereuses lorsqu ils sont mouill s Plus pr cis ment v rifiez bien que les isolents sont en bons tats et remplac...

Page 17: ...gnal du g n rateur sur la canalisation ou sur le c ble le r cepteur est maintenant pr t l emploi Remarque Quand le r cepteur est plac une distance pr cise de la canalisation cible les valeurs de profo...

Page 18: ...pour le r cepteurs RD5000 qui peut am liorer la performance la stabilit et peut inclure de nouvelles caract ristiques Centros Manager contient la derni re version du logiciel et pour t l charger le l...

Page 19: ...icat trouvez le num ro de s rie du RD5000 dans la fen tre du gestionnaire de l appareil et d veloppez les contenus D veloppez les validations eCAL et double cliquez sur la date d ex cution de l eCAL p...

Page 20: ...ment de piles alcalines utilisez uniquement la taille et le type de pile sp cifi s Ne jamais m langer des piles rechargeables et alcalines Ne jamais essayer de recharger des piles alcalines Piles rech...

Page 21: ...les marques Radiodetection Pearpoint Telespec Bicotest Riser Bond Dielectric Mark Products et Warren G V Radiodetection garantit par la pr sente que ses produits sont exempts de d fauts de mat riel et...

Page 22: ...c le produit vii Une utilisation du produit avec des accessoires des quipements p riph riques et d autres produits d un type dans un tat ou d un niveau diff rent de celui prescrit par Radiodetection v...

Page 23: ...earpoint sales us spx com www pearpoint com Radiodetection Canada 344 Edgeley Boulevard Unit 34 Concord Ontario L4K 4B7 Canada Tel 1 905 660 9995 Toll Free 1 800 665 7953 rd sales ca spx com Radiodete...

Reviews: