Diagnosis & Troubleshooting
56
DISPLAY
Fault Code
Explanation / Recommended Testing Procedure
F01
Short-circuited Motor TRIAC on Module Board
• Verify Drive Motor connections and wiring. See “Component Testing”.
• Open the door of the washer-dryer and verify the drum spins freely and is not hitting anything.
F02
Blocked Motor/Tachometer Open/Short-Circuited
• Verify Drive Motor connections and wiring. See “Component Testing”.
• Verify motor operation. Refer to “Test Running the Main Motor with AC Voltage” pg 47.
• Open the door of the washer-dryer and verify the drum spins freely and is not hitting anything.
F03
Wash NTC Sensor Open/Short-Circuit
• Verify NTC Connections and wiring. See “Component Testing”.
F04
Both Empty and Over Flow Signals Present
• Verify Pressure Switch connections and wiring. See “Component Testing”.
F05
Blocked Pump/Pressure Switch Stuck on Empty
• Check Pump Pre-Chamber for blockage. See “Component Access”.
• Verify pump connector and wiring. See “Component Testing”.
• Verify Pressure Switch connections and wiring. See “Component Testing”.
F06
Selector Binary Code Not Found
• Verify Program Selector connections and wiring, See “Component Testing”.
F07
Not Applicable
F08
Missing or Incorrect ON/OFF Switch Signal
• Verify ON/OFF Switch connections and wiring. See “Component Testing”.
See “Explanation of the Fault Codes” on the previous page to determine the Fault Code that the washer-dryer is displaying. Then, follow the recommended
testing procedure to troubleshoot the problem. Call Westland Sales if the machine continues displaying the Fault Code.
Fault Code / Testing Procedure Chart
Summary of Contents for WD2000S
Page 4: ...ii ...
Page 18: ...12 N O T E S ...
Page 32: ...26 N O T E S ...
Page 45: ...39 N O T E S ...
Page 46: ...40 N O T E S ...
Page 71: ...65 N O T E S ...