Component Testing Procedures
42
• Make sure that the power cord is fi rmly plugged into a live circuit with the proper voltage.
• Check for a blown household fuse or circuit breaker that has tripped.
• Make sure that the dryer vent is properly installed and clear of lint obstructions. (WD2100 and
WD2000S Only.)
When testing, follow these instructions:
• Resistance tests MUST be made with the power cord unplugged from the outlet, and the wire con-
nector removed from the Module Board.
• All tests should be made with a VOM (volt ohmmeter) or DVM (digital volt ohmmeter) having a
sensitivity of 20,000 ohms-per-volt DC or greater.
• BEFORE replacing any component, ALWAYS check for wire connectors that are not pressed tightly
into their terminals. Tests MUST be made with ALL connectors attached. Look for broken or loose
wires, failed terminals, or wires that are not pressed into their connectors far enough.
If the readings you obtain with the following tests match the specifi ed range, the tested component is
operating correctly.
If the readings you obtain are not in the specifi ed range, call Splendide Service at 1-800-356-0766
(503-655-2563) ext. 5 for further assistance.
Have the Model and Serial Number of your machine
ready when you call.
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death
or electrical shock.
WARNING
!
Introduction
Before testing the components, ALWAYS:
Your Test Results
Summary of Contents for WD2000S