Component Testing Procedures
41
C o m p o n e n t T e s t i n g P r o c e d u r e s
Connector Locations on the Module Board
Component
Connector
Fault Code(s)*
1. Door Switch
CNJ
N/A
2. Power in from Surge Protector
CNK
N/A
3. Pressure Switch
CNI
F04, F05, F10, F14
4. Heating Element
CNH
F15
5. Main Motor
CNG
F01, F02
6. Pump / Fan Motor
CNF
F05, F11, F13
7. Water Valves
CNE
N/A
8. Push Buttons, Dry Time/Water Temp. Selectors
CNC
F08
9. Cycle Selector
CND
F06
10. NTC Sensors / LED’s
CNB
F03, F13
* For more information about how to read Fault Codes and what they mean, see the “Fault Code Chart”
(Continued on the next page)
The following tests are performed by taking ohm readings on the Module Board connections listed below.
The Module Board can be accessed once the back panel has been removed. See “Component Access Locations.”
Summary of Contents for WD2000S