Accessing the Components
32
Removing the Pressure Switch
Unclip the pressure switch from the cabinet. Keep the plastic
bracket attached. (Fig. 4-16) Using pliers, squeeze the clamp to
disconnect the black hose from the bottom of the pressure switch.
(Fig. 4-17) Be careful not to pull up on the hose too much, or it
may become disconnected from the bottom of the drum.
Next, squeeze the tabs (Fig. 4-17) to remove the wiring harness
connectors from the pressure switch. Remove the plastic bracket
that clips the pressure switch onto the cabinet, then reinstall it onto
the replacement pressure switch. Be sure to check the wire con-
nector for a tight connection after re-installation.
Pressure Switch
The Pressure Switch is located on the top-right, front corner of the machine. The pressure switch can be accessed once the top is removed.
IMPORTANT!
It’s very important to note the
orientation of the wiring on the
valves for re-installation. If the
wiring is switched the water
temperatures will be incorrect, and
on condenser machines, the dry
cycle will not operate correctly.