5.1.4 – Solar heating
The SplashMe Automation Controller is a fully functioning solar heating controller.
The SplashMe Automation Controller will automatically maintain the pre-set water
temperature entered in the App settings.
The SplashMe Automation Controller periodically measures the water temperature by
activating the filter pump for several minutes when the filter pump is typically off.
Whenever the filter pump is functioning, the SplashMe Automation Controller measures the
water temperature using the in-built temperature sensor. The SplashMe Automation
Controller will then control the solar heating to achieve and maintain the pre-set level.
If no filter pump schedule is running, the SplashMe Automation Controller will periodically
measure the water temperature by activating the filter pump for several minutes.
See below for more detail on common solar setups.
Independent – Solar Pump
This type of system is the most common configuration. It uses its own suction and return
lines and will have an independent solar pump which works independently of the main filter
pump.
Any of the auxiliary outputs (AUX 1, 2, 3 and 4) can be assigned to control a solar pump.
Ensure that the pump power requirements do not exceed the maximum ratings of the
auxiliary outputs.
Note the connection outlet number so it can be correctly assigned when setting up the
SplashMe App.
Warning
All plumbing to be done by qualified persons