SplashMe Automation Controller 1.0 | Installation and Operating Instructions
© Nymet Innovations Pty Ltd 2019 | Revised November 2019
33
Section 5 – Connecting equipment
5.1- Connecting 240V equipment
5.1.1- 240V Auxiliary connections
Plug adapters
The SplashMe Automation Controller is supplied with 5 x 10A plug adapters. These adaptors
enable users to connect equipment with an Australian 3 pin plug to any of the 5 output IEC
appliance connectors located at the base of the device.
Primary input
The Primary Input lead at the rear of the device supplies power to the SplashMe Automation
Controller. This plug also supplies power to the single speed filter pump (up to 2 kW).
Input 1-3
Supplies power to equipment connected to AUX 1-3. This input is required to be connected
to an RCD protected socket outlet that is on a dedicated 16A circuit and circuit breaker. Use
this plug if equipment will be connected to AUX 1, AUX 2 or AUX 3. This input will allow a
total of 10A to be used on the AUX 4 output.
Input 4
Supplies power to equipment connected to AUX 4. This input is required to be connected to
an RCD protected socket outlet that is on a dedicated 16A circuit and circuit breaker. This
input is only required if AUX 4 will be used. This input will allow a total of 10A to be shared
across the three AUX outputs.
Instructions
1.
Plug in one of the supplied power leads into the RCD protected 10A 240V socket
outlets and connect the other end to the auxiliary inputs required
Warning
All electrical connections and installations to be done by a
licenced
electrician
Auxiliary inputs to be connected to a separate 16A circuit and
circuit breaker