6.6.20 Request unit Scaling
Description:
The host requests that the firmware report the unit scaling.
Direction:
Host to supply
Syntax:
<STX><28><,><CSUM><ETX>
Example:
<STX>28, <CSUM><ETX>
Response:
<STX><28><,>< ARG1><,>< ARG2><,><CSUM><ETX>
Where:
<ARG1> =0-65535 in ASCII format representing the voltage full-scale
value.
<ARG2> =0-65535 in ASCII format representing the current full-scale
value.
Example:
<STX>28,7000,856<CSUM><ETX>
Voltage full scale = 70.00kV
Current full scale = 8.56mA