5.5.3 Request Total Hours High Voltage On
Description:
The host requests that the firmware sends the present value of the Total
Hours High Voltage On.
Direction:
Host to supply
Syntax:
<STX><21><,><ETX>
Example:
<STX>21,<ETX>
Response:
<STX><21><,><ARG1>< ARG2>< ARG3><ARG4><ARG5>
<.><ARG6><,><ETX>
Where:
<.> = ASCII 0x2E
ARGx =0-9 in ASCII format
Example:
<STX>21,99999.9,<ETX>
118080-001 REV A
Page 43 of 95
Summary of Contents for SLM SERIES
Page 15: ...SLM MANUAL 6 118073 001 Rev C Figure 2 2 Unit Dimensions 1200W ...
Page 19: ...SLM MANUAL 10 118073 001 Rev C Figure 3 3 Local Programming via External Voltage Source ...
Page 20: ...SLM MANUAL 11 118073 001 Rev C Figure 3 4 Remote Monitoring ...
Page 40: ...Figure 9 Web Page 1 Contact Information 118080 001 REV A Page 13 of 95 ...
Page 98: ...Request Faults 68 20 ASCII 118080 001 REV A Page 71 of 95 ...