40
Storage Procedure: SC-1 powdered preservative (good for 6 months):
1. Fill a bucket with 4 gallons (15 l) of fresh unchlorinated water, leaving at least 4” (10cm) to
the top of the bucket. Mix 2 lbs (1kg) SC-1 storage chemical compound into the water in the
bucket. Note that it will take about an hour for most of the chemical to dissolve.
2. Perform two fresh water flushes to prepare the system for cleaning.
3. Install the service hoses from the service kit onto the service inlet and outlet quick connec-
tions and put the other end in the bucket with the SC-1. Turn the yellow service valves so they
point at the service fittings
4. Confirm the pressure relief valve on the high pressure
pump is open one full turn.
5. Flip the toggle switch on the main control box to “Service” to turn on the pump and circulate
the storage chemical in the system for at least 20 minutes.
6. After 20 minutes flip the service switch off.
`
Clean Up:
Turn the service valves to the off position (half way)
Remove the service hoses and replace the dust caps.
Remove the filter bowls, rinse with the storage solution and reinstall with clean dry filters.
This should be a clean operation so you do not introduce bacterial into the filter bowls.
Wear clean disposable gloves if available and/or wash your hands before starting
Discard the remaining storage liquid in the bucket to a suitable drain.
Turn off the power to the system.
LEAVE THE PRESSURE RELIEF VALVE OPEN 1 FULL TURN AND LEAVE A NOTE ON
THE SYSTEM SHOWING THAT IT IS FULL OF STORAGE SOLUTION AND THE DATE.
ALSO MAKE A NOTE IN THE LOG BOOK.
Discharge/Service
Outlet
Feed/Service
Inlet
Long Term Storage Procedures