Tank Level not accurate
Tank Level not calibrated
Domestic water pump run-
ning
Water tanks sloshing while
underway, no baffles in
tanks
Tank sensor failed
Calibrate tank level according
to calibration instructions
Stop domestic water pump
and check tank level
Re-check tank level accuracy
while vessel in in port and sea
state is calm
Replace sensor
SYMPTOMS
PROBABLE CAUSE
REMEDY
Troubleshooting Spectra Connect
Tank Level shows ‘ ! ‘
Tank Level sensor disabled
in Settings
Verify tank level sensor is
installed, and enable the tank
level sensor
Device IP in Support Menu
reads ‘NIL’
Control board not connect-
ed to router or switch
Control board not receiving
IP address from router or
switch
Connect the control board to a
router or switch according to
the Networking instructions
Cycle power on the water-
maker with the network cable
connected
Power suddenly drops out
and watermaker restarts
Electrical short, or failed
boost pump
Electrical short, or failed
solenoid valve
Electrical short, or failed
pressure sensor
Electrical short, or failed
speed control
Electrical short, or failed
salinity probe
Disconnect boost pump wires
from control board and cycle
power. Check boost pump for
electrical short.
Replace Boost Pump
Disconnect solenoid valves
from control board and check
valve for a short.
Replace valve
Disconnect speed control and
cycle power. Check speed
control for electrical short.
Replace Speed Control
Disconnect salinity probe
wires from control board and
cycle power.
Replace Salinity Probe