40
To access this information about your watermaker while it is running press the
<
or
>
buttons
to scroll through the pages.
Nominal Operating Parameters
Parameter
Minimum
Maximum
Product Quantity
11 GPH (41 LPH)
13 GPH (49 LPH)
Product Quality
N/A
750 ppm
Feed Pressure
N/A
110 psi (7.6 Bar)
Boost Pressure
15 psi (1.1 Bar) or Greater
Filter Condition
100%
Amp Draw
19A @ 12.5vdc; 9.5A @ 25vdc
8. When the Run Cycle completes, or by pressing
’
Stop
’,
the system will start to Fresh Water
Flush.
You MUST FRESH WATER FLUSH the watermaker AFTER EACH USE, or se-
rious damage can occur
8. After Fresh Water Flushing the system will enter the
‘
Auto Store
’
mode, and the interval
timer until the next scheduled flush will show on the screen.
Normal Operation—Cont
’
d