53
“
Salinity High
”
•
High product water salinity
•
Chlorine damage to mem-
branes
•
Defective salinity probe or
cable, cable disconnected
•
Check for low feed pressure
•
Check for leaks at high pres-
sure hoses
•
Remove and clean probe con-
tacts. Check calibration
•
Check cable connections
•
Clean membrane
SYMPTOMS
PROBABLE CAUSE
REMEDY
“
System Stalled
”
(“
system stalled
”
may alarm
when using the control pan-
el to run system for servicing
with the pressure relief
valve open–
use manual
override switch instead)
•
Pressure relief valve open
•
Intake thru
-
hull closed
•
Airlocked system
•
No signal from Rotoflow
meter
•
Close pressure relief valve
•
Check thru
-
hull
•
Purge air
•
Clean or replace Rotoflow
meter
•
Check brine discharge
•
Clean membrane
“
High Pressure
”
•
Blocked brine discharge
•
Fouled membrane
“
Voltage Too High
”
“
Voltage Too Low
”
•
Battery voltage too high or low
•
Loose wires or poor connec-
tions
•
Charge batteries
•
Check charging voltage
•
Check power connections
“
Re
-
starting
”
•
No signal from Rotoflow meter
at startup.
•
System airlocked
•
See remedy above for
“
system
stalled
”
“
Service Prefilter
”
•
Clogged filters or sea strainer
•
Loose or defective pressure
sensor wires
•
Dead Boost Pump
•
Kinked Hose
•
Grass in through hull or sea
strainer inlet check valve
•
Install new filters
•
Check sensor wiring
•
Dump water from filter bowls,
run again, check for good flow
•
Check Boost Pump operation
•
With clean filters, recalibrate
Bimini 300 Fault Alarms
Summary of Contents for Bimini 300
Page 1: ......
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 10: ...10 Installation Notes ...
Page 19: ...19 John Guest Super Speedfit Fittings ...
Page 67: ...67 Wiring Schematic ...
Page 77: ...77 Parts 1 SO HPP PR10 ...
Page 78: ...78 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...