Page 1: ......

Page 2: ...2 ...

Page 3: ...d boats Non sparking switches and a state of the art brushless DC motor are utilized to make sure all components comply with the strictest federal guidelines This safe convenient system is versatile modular and easily maintained The Bimini 300 is also fully automated with the Spectra Connect system mak ing it the simplest watermaker ever to operate and maintain as well as allowing mobile access an...

Page 4: ...4 ...

Page 5: ...screen Spectra Connect Quick Start Guide Run Mode Select your desired Run Mode to start making water and filling your tanks See details on Run Mode options on p 37 Spectra Connect Modes and Definitions Auto Store After the watermaker fresh water flushes it will start a countdown timer that can be seen on the Home screen The timer indicates the next programmed fresh water flush if the water maker i...

Page 6: ...6 ...

Page 7: ...will be void if the installation does not meet this requirement 3 Follow the wire gauge charts in the instructions Using larger wire than specified is accepta ble 4 If you are separating the Clark Pump membrane assembly please review the high pressure tube assembly instructions Improper assembly will cause failure 5 Run test then sea trial the complete system before assuming it is operational If t...

Page 8: ...8 ...

Page 9: ...or Calibration 32 Salinity Calibration 34 Product Flow Calibration 35 Networking 36 Normal Operation 38 Maintenance Storage and Troubleshooting Maintenance 43 Introduction to Spectra Chemicals 46 Storage Procedures 48 Winterizing with Propylene Glycol 49 Membrane Cleaning Procedure 50 Suggested Spares 51 Troubleshooting 52 Alarm Override and Manual Operation 53 Bimini Flow Test 55 Poor Water Quali...

Page 10: ...10 Installation Notes ...

Page 11: ...stallation Lay out the system Before starting the installation identify where each module and compo nent will be placed Ensure that there is enough clearance around the components for remov al of filters and system service Make sure you have adequate tubing and hose before starting Additional parts may be ordered Getting Started Bimini 300 Shipping List Bimini Feed Pump Module 10 Clark Pump and Re...

Page 12: ...mittent flow restrictions air bubbles contami nants and will void the warranty For racing boats and high speed boats traveling above 15 knots a retractable snorkel type thru hull fitting is preferred because it picks up water away from the hull The brine discharge thru hull should be mounted above the waterline along or just above the boot stripe to minimize water lift and back pressure Double cla...

Page 13: ... over 113 F 48 C Sea Strainer and Boost Pump Module Mount close to the intake through hull below the waterline in a location that can handle water spillage during service The boost pump power cable will connect to the feed pump module Fresh Water Flush Module The fresh water flush module may be located in any convenient location near the feed pump module It should be mounted with the filter housin...

Page 14: ...k occurs Allow for easy access to the pressure relief valve The Clark pump and membrane module comes complete with a mounting system Be sure to use the supplied washers on the rubber feet Pressure Relief Valve Components continued Clark Pump and Membrane Remote Touchscreen The remote control panel can be mounted anywhere dry and convenient Cut a 5 5 8 12 7 cm wide by 3 1 4 7 62 cm high opening for...

Page 15: ...o the brine overboard fitting Plumbing Schematic Flush water from ship s pressure water system 25 psi 2bar minimum Use part of the 25 feet 8 meters of 1 2 inch vinyl hose pre fitted with a 1 2 inch John Guest stem fitting to connect the feed pump to the Clark Pump feed water inlet see following pages Use the 1 2 inch vinyl hose with the Quick Connect fitting be tween the Z Ion fresh water flush mo...

Page 16: ...oat is unattended for the fresh water flush system to function properly The domestic fresh water pump must be able to deliver 1 5 gallons per minute 6 LPM at 25 PSI 1 7 bar Attaching 1 2 inch vinyl hose to sea strainer using the 3 8 John Guest stem fitting and hose clamp found in installation kit Attaching 1 2 inch vinyl hose to Z Ion fresh water flush module with the pre fitted Quick Connect fitt...

Page 17: ...tting from the installation kit From the feed pump to the Clark Pump feed water inlet use the remaining 1 2 inch vinyl hose with the 1 2 inch John Guest stem fitting pre fitted with a ferrule Insert the pre fitted end into the feed pump Figure 1 and the 1 2 John Guest stem fitting and hose clamp from the instal lation kit for the Clark Pump feed water inlet Figure 2 Refer to John Guest assembly in...

Page 18: ...ream until the Con nect controller determines the product water is below 750 PPM salinity Once below 750 PPM the Connect controller opens the diversion valve and product water is diverted into the fresh water tank The salinity probe must be mounted in a vertical position with the cable coming out the bottom If the Clark Pump Membrane Module is mounted vertically or upside down the diversion valve ...

Page 19: ...19 John Guest Super Speedfit Fittings ...

Page 20: ...ccess to the motor speed control Power inlet harness with terminal block Boost pump cable Yellow Brushless Motor speed controller Spectra Connect controller Inside control Run Auto Manual Service toggle switch Electrical Z ION Connector with green band Left unused if your system was not ordered with the optional Z ION Tank Full Switch Terminal Block Green Orange Tank Level sensor 5vdc Red Signal W...

Page 21: ...t 30 5 M cable for the Connect display Diversion Valve and Rotoflow Cable 5 conductor Red Z Ion power and signal cable 3 conductor Green Cables are shown coming out of the bottom of the Feed Pump Module Fresh water flush sole noid cable 2 conductor Blue 100 33 3M cable with connectors for the connect display The Bimini 300 has three ports that can be viewed when looking down inside the Feed Pump M...

Page 22: ...her Size cables ac cordingly Mount the main power terminal block in a junction box or on a bulkhead adjacent to the feed pump module Make sure that this is a dry location well above bilge level and not subject to wa ter spray Be sure to install the terminal block cover Check the wire size chart for appropriate wire sizes DC power feeds should be uninterruptible to insure proper operation of the au...

Page 23: ...ng the wire or sharp corners where the wire can chafe through while the vessel is under way Turn power OFF to the system Connect the ethernet cable to back of the display in the open jack Connect the opposing end of the ethernet cable to the RJ12 port labeled DISPLAY in the feed pump module Remote Display Plugin ...

Page 24: ...ess cover For Instructions on Auto Fill mode and installing a Tank Low switch see Auto Fill mode instructions later in this manual Watermakers should never be run unattended Your watermaker comes with the top mounted Tank Full Switch EL SWT LV and is de signed to be mounted to the top of the water tank The side mounted float switch EL SWT SMLV can be sourced from your local dealer or Full Service ...

Page 25: ... user commands Drill 5 8 hole into the side of the fresh water tank that is being filled by the watermaker This can be installed wherever there in convenient access to the tank approximately 2 3rds of the way down from the top of the tank Drill 5 8 hole Tank Switch Installation 2 3 The float switch must be connected to the Tank Switch 1 terminals on the Spectra Connect control board at the Feed Pu...

Page 26: ...sh Water Tank Domestic Water Pump Connect Red to Red White to White Black to Black If a 2nd Tank Level Sensor is going to be installed it should be installed at the base of the second tank If monitoring 2 water tanks they must be isolated from each other with a valve to read properly The wiring connections for the second Tank Level Sensor are located inside the Spectra Connect control box See Syst...

Page 27: ...e section Dry Testing with an Artificial Ocean 1 First Check That Seacock is open Toggle switch on the Feed Pump Module is in the Run Auto position Domestic fresh water pressure system is on 2 Open pressure relief valve 1 2 turn and remove the Green Tag and washer 3 Turn on the power to the system and the Spectra Connect screen will display Has the sys tem been stored with chemicals Press Yes to s...

Page 28: ...stem Shut down the system and repair any leaks you find Check the strainer and the brine discharge for water flow The system should fully prime with in 60 90 seconds and all air should be out of the feed water hoses The feed pump will sound smooth There should be no bubbles anywhere in the intake hoses If the feed pump continues to sound rough find the reason before continuing Inspect the system f...

Page 29: ...o fill the bucket with fresh water from the brine discharge service hose hose attached to Clark Pump Press Stop when the bucket is full 6 Mix the salt to the proper proportion or use an aquarium hydrometer to adjust the salinity level to a specific gravity of 1 025 7 Remove the fresh water flush hose from the fresh water flush module or Z Ion at the Quick Connect fitting and connect the intake ser...

Page 30: ...ean and all thru hulls are open before proceeding 2 Follow the steps in Figures 1 4 below to initiate the Calibration Sequence Sensor Calibration Many of the settings on your system have been pre calibrated during standard factory testing however there are a few settings that will vary based on the installation vessel and other onboard conditions If the system has just been installed you must cali...

Page 31: ... properly 3 If the display alarms Service Prefilters then the fresh water pump is not supplying enough water and the feed pump needs to be slowed down Slowing down the pump during a Fresh Water Flush You can slow down the feed pump from the Spectra Connect Display s Dealer Access Settings Logging into the Dealer Access Settings is outlined in the Spectra Connect Programming section of the manual O...

Page 32: ...ge in a clean cup Measure the salinity of the brine discharge and confirm that it is below 1000ppm using a calibrated hand held TDS meter If the flush duration needs to be increased seek the Spectra Connect programming instruc tions in this manual Flush Adjustments continued Tank Level Sensor Calibration 1 Press the Menu Button 2 Press the Calibrate Sensors Button 3 Press the Tank Level 1 button 4...

Page 33: ...Feet Meter field to enter the tank height in feet meters Press the Inch cm field to enter the height in inches Ex If the Tank height is 150cm Enter 1 in the field labeled Meter Enter 50 in the field labeled cm 7 Press Submit and confirm your entry matches your measurement 8 You must save all changes when prompted after exiting the settings menu ...

Page 34: ...sampling valve was installed 7 Touch the PPM field and enter the reading taken above 8 Press Proceed to store the new calibration value You must save all changes when prompt ed after exiting the settings menu Fig 1 Fig 2 Fig 3 Fig 4 Salinity Calibration 1 Press the Menu Button 2 Press the Calibrate Sensors Button The Salinity probe has been calibrated at the factory during testing and is not norma...

Page 35: ... 3 7 Touch the seconds field to enter the seconds it took to fill the container Only enter the seconds ex 3 min 15 sec should be entered as 15 8 Press Proceed You must save all changes when prompted after exiting the settings menu 3 Press the Product Flow Button The Product Flow sensor has been calibrated at the factory during testing and isn t normally required during commissioning If the product...

Page 36: ...hernet cable from jack labeled network to your ship s router or networking switch 3 Turn power to the sys tem back on 4 Follow the screen prompts below Fig 1 Fig 2 Fig 3 Note Your Spectra Connect is only available when your device is connected to the same local network as the Spectra Connect control board If you have difficulty connecting to your water maker control application double check the th...

Page 37: ...ons you press on your web browser will be controlling your watermaker Caution If operating your watermaker from a computer phone or tablet you must keep the tab open while the system is in operation and the volume turned up on your de vice in order to hear any audible alarm faults Connecting to the existing Network Cont d Ship s Router or 6 Connect your computer tablet or smart phone to the local ...

Page 38: ...mestic pressur ized water system is turned on 2 Press the Start button then select the desired operating mode Runs your watermaker until the Tank Full switch closes fresh water flushes the system then goes into Auto Store mode and the Flush Interval timer starts This is the default mode of operation Gives you the option to run for a preset amount of time or a preset volume of water to be produced ...

Page 39: ... Valve Status CLOSED Diversion Valve Status OPEN 6 When the Product Water Quality is below the programmed threshold the Diversion Valve opens allowing water to enter the tanks and the screen image changes 7 Pressing the Page Left or Page Right arrows will show a different screen with differ ent operating information for your watermaker Verify that the system is operating according to the factory s...

Page 40: ... A 110 psi 7 6 Bar Boost Pressure 15 psi 1 1 Bar or Greater Filter Condition 100 Amp Draw 19A 12 5vdc 9 5A 25vdc 8 When the Run Cycle completes or by pressing Stop the system will start to Fresh Water Flush You MUST FRESH WATER FLUSH the watermaker AFTER EACH USE or se rious damage can occur 8 After Fresh Water Flushing the system will enter the Auto Store mode and the interval timer until the nex...

Page 41: ...rt Menu will allow the system to be operated in Auto Fill WARNING NEVER RUN YOUR WATERMAKER UNATTENDED EQUIMENT CAN BE SERIOUSLY DAMAGED AND IT IS POSSIBLE TO SINK THE VESSEL Use extreme caution when operating in Auto Fill mode In Auto Fill Mode the Spectra Connect will automatically fill your water tank stop itself fresh water flush return to Auto Store mode with the flush interval timer running ...

Page 42: ...an the expected time of operation in the Auto Store mode If there isn t enough fresh water in your tank seawater will be drawn in and the system will not be flushed with fresh wa ter The Bimini 300 requires about 7 gallons 26 liters for each flush The boat s pressure wa ter supply must be on and stay on while the system is in Auto Store mode If these conditions cannot be met then pickling with SC ...

Page 43: ... semble dry to impede corrosion Check frequently during operation The Pre filters Service the pre filters as soon as possible after the pre filter condition graph begins to rise If the filter condition graph gets all the way to Replace the machine will slow down When display reaches Replace a second time the alarm will sound and the system will shut down to prevent damage To service the filters cl...

Page 44: ...on the back of the Clark Pump have captive nuts and washers which compress the O rings without turning the entire fitting If a tube fitting leaks it can sometimes be resealed by just tightening You must use two wrenches a 13 16 inch wrench to hold the base and a 7 8 inch wrench to turn the compression nut The 13 16 inch wrench will need to be thin so as not to interfere with the compression nut If...

Page 45: ...r or a higher salinity seawater source can cause high pressure Low product flow is usually due to low voltage a worn feed pump or worn Clark Pump Due to the unique design of your Spectra system low product water volume is typically not a membrane problem but frequently related to low voltage a worn feed pump head or a worn Clark Pump Always perform a flow test before cleaning your membrane Test to...

Page 46: ...structions for Storage Procedure Spectra systems should be stored with propylene glycol if freezing is likely to occur Propylene glycol can be used instead of Spectra SC 1 storage chemical for storage in any climate and treatment is effective for one year Propylene glycol is a food grade antifreeze used to winter ize RV s boats and cabins Do not use ethylene glycol automotive antifreeze which is t...

Page 47: ...xperience low product water quality cleaning with SC 2 usually removes all traces of propyl ene glycol and returns the salinity to the level it was before storage with propylene glycol See the Membrane Cleaning Procedure Cleaners Avoid unnecessary cleaning and avoid cleaning as a diagnostic tool SC 2 is an alkaline cleaner used to remove light oil grime and biological growth It is most effective i...

Page 48: ...rol switch on the control box to SERVICE The solution will be drawn from the bucket with the service hose and re turned to the bucket from the brine discharge service hose Circulate the storage chemical in the system for approxi mately 20 minutes Stop the feed pump by moving the switch back to the RUN AUTO position Clean Up Remove the brine discharge service hose from the Clark Pump and replace th...

Page 49: ...water Stop the pump by moving the switch back to RUN AUTO Add more propylene glycol to the intake bucket if necessary 7 Lead the brine discharge service hose into the intake bucket of propylene glycol Move the switch back to SERVICE The service hose will now draw propylene glycol solution from the bucket and the brine dis charge service hose will return it Run the feed pump and circulate the propy...

Page 50: ...5 Make sure that the pressure relief valve on the Clark Pump is open un pressurized 6 Mix the cleaning chemical in the bucket If possible heat the solution to 120 F 49 C 7 Move manual switch on the Feed Pump Module to SERVICE SYSTEM The intake service hose will draw solution from the bucket and the brine discharge service hose will return it Circulate the solution through the system in this manner...

Page 51: ...ols and membrane cleaning chemicals One replacement strainer screen replacement O ring for strainer screen and replacement O rings for the filter housings Common Parts Item Part Number SC 1 STORAGE CHEMICAL KIT CHEM SC1 SC 2 CLEANER KIT CHEM SC2 SC 3 CLEANER KIT CHEM SC3 BASIC CRUISE KIT A KIT BCK A OFFSHORE REBUILD KIT KIT OFFSH 5 MICRON FILTER FT FTC 5 CHARCOAL FILTER FT FTC CC 6 STRAINER SCREEN...

Page 52: ... hand held tester if over 500 PPM for 1 hour contact factory Close pressure relief valve No lights or display system does not operate Remote display not con nected No power to control box Check display cable connections at back of display and at control box Check and reset main DC supply breaker Check for voltage 12 or 24 VDC at control box power input studs Try manual toggle switch If pump runs t...

Page 53: ...ressure relief valve Check thru hull Purge air Clean or replace Rotoflow meter Check brine discharge Clean membrane High Pressure Blocked brine discharge Fouled membrane Voltage Too High Voltage Too Low Battery voltage too high or low Loose wires or poor connec tions Charge batteries Check charging voltage Check power connections Re starting No signal from Rotoflow meter at startup System airlocke...

Page 54: ...es not cycle if air is continuously present in the intake line or if the feed pump is excessively noisy Always discard the product water for the first few minutes of operation as the initial product water may not be potable Take a water sample by loosening the 1 4 inch product tube fitting at either the feed pump module or the membrane outlet Check it with a handheld salinity meter or taste it The...

Page 55: ...continue with this test You will need a graduated bucket either a graduated pitcher or large measuring cup and a stop watch Log the voltage at the feed pump at the same time Confirm at least 12 5 Volts at the Termi nal Block on 12 Volt DC systems 25 volts on 24 Volt DC systems Take two measurements and compare them with the table on the following page The first meas urement is the product flow alo...

Page 56: ...is 97 seconds Example It took 53 seconds to collect 12 liters of total flow 60 53 x 12 13 58 LPM 3 Recovery Rate Product Flow Total Flow Recovery Rate Example 6 5 GPH product flow 063 or 6 3 1 7 GPM total flow x 60 you must first multiply total flow by 60 to convert from GPM to GPH pressure relief valve open turn In order to make good quality product water you need the proper amount of feed water ...

Page 57: ...n flush water They must be of proper specification to be suitable See page 64 There is no test for chlorine damage except the process of elimination of other causes DIRTY OR SCALED membranes A dirty foreign material scaled mineral deposits or contaminated bacterial growth membrane can result in poor water quality and ab normal operating pressures If operating pressures are above normal then cleani...

Page 58: ... and the Clark Pump The purpose of the feed line accumulator is to reduce the spikes in the feed pressure caused by the cycling of the Clark Pump If the accumulator is not properly charged it can lead to pres sure spikes and system shut down The accumulator has a Schrader air valve like a car tire which allows the internal air bladder of the accumulator to be pre charged The accumulator should be ...

Page 59: ...re filter will plug up water production and quality will drop and the system pressure will change dramatically In blue water conditions the pre filter may only need to be changed every week or two When operated for only an hour or two a day in inland or near shore waters the trapped plankton will begin to decay in the filters long before the elements plug up The decaying plankton and bacteria will...

Page 60: ... there are aftermarket filters which are very close to but not exactly the right dimensions and they will not seal in the housing If you skimp on the charcoal filter you risk damaging a 600 00 membrane on the first flush The other factor is the flow rate that the filter can handle Because the chlorine is adsorbed by the charcoal it must remain in contact with the charcoal for a sufficient period o...

Page 61: ...r easier than ever The onboard time clock feature allows for temporary power interruptions without detrimental effects on the system In some cases your watermaker will continue to function in its last known operating state The Spectra Connect has built in data logging allowing for easy access to historical operating data which can indicate a wearing component or spares to be carried along before a...

Page 62: ... sensor System stalled alarms occur when the control board does not sense any product water being produced and shuts down to protect the pump from running dry Poor Quality Fault Disables the High Salinity shut down fault in the event that the salinity probe has failed or cannot be calibrated within range NOTE The diversion valve will always be active when this fault is disa bled ALWAYS VERIFY PROD...

Page 63: ...Clear Statistics Resets all of the Estimated Maintenance Intervals back to 100 This feature should only be used on a brand new system Change Username password Changes the default username and password If you forget your changed username and password a Factory Reset will revert back to the default username and password Set MFD Changes the Manufactured Date on the system This should only be adjusted...

Page 64: ...nsors which read the remaining in the tank and the tank switches which allow the system to turn on off automatically Boost Pressure Setup Enable alternate Boost Pressure sensors change the Low Vacuum Limit or Boost Pres sure Setpoint CAUTION Permanent damage to the pump can occur if this setting is adjusted Consult the factory before making any adjustments Low Vacuum Limit The minimum boost pressu...

Page 65: ...bles or disables an optional power sensor after it is installed PH ORP Enables an optional pH or ORP meter after it is installed Z Ion Enables or Disables the optional Z Ion system after it is installed If the Z Ion is enabled you should also adjust the Flush Interval to 30 days Tank Level Monitors Tank Setup Enable disable tank sensors Enable Tank Switch High Enable disable tank switch high If th...

Page 66: ... intake line for restrictions blockages or air leaks Close Pressure Relief Valve on Pump Confirm controller settings correct SERVICE PREFILTER FAULT The Service Prefilter fault is triggered if Inlet Pressure boost pressure Low Vacuum Limit If the Service Prefilter fault triggers the system goes to low production mode if it is running in high production mode or stops the operation if it is already ...

Page 67: ...67 Wiring Schematic ...

Page 68: ... voltage limits 10 32vdc Outputs 5VDC 2000mA Total for all outputs VLV 1 2 1 Amp DC priming valve solenoid AUX 1 3 1 Amp DC auxiliary output Never connected anything to the Spectra Connect without factory approval Serious dam age can occur ...

Page 69: ...ng SUB CT Z HPILHA CT 300 Quick Disconnect PL TEE 1 2TJG John Guest 1 2 inch swivel tee PL STA 12Tx38NJ 1 2 Tube Stem x 3 8 NPT adapter John Guest Accumulator Hose 20 inches 1 2 inch vinyl hose PL HS 1 2VN 2 brass ferrules PL HF 75lDX1BR 2 1 2 inch hose barb tube adapters PL HBA 1 2Tx1 2 5 inches of 3 4 inch spiral wrap EL LT 3 4SW Hose clamps may be substituted for the brass ferrules which are cr...

Page 70: ... 2 NPT X 3 8 NPT CLOSE NIPPLE NYL FT FHB 3PCSHSS MOLDED FILTER BRACKET PL SWF 1 2X1 2 1 2 NPT X 1 2 TUBE SWIVEL ELBOW PL NLT 1 2LP 1 2 LOW PRESSURE TUBE HD OTH 1 4TS1D 1 4 20 x 9 16 NYLON THUMB SCREW 1D EL MTR 1 5BLM24 1 5HP BRUSHLESS MO TOR 24V FM CT BDCMTBP CATALINA BDC MOTOR ADAPTOR FM CT BDCMAD CATALINA BDC MOTOR BASE PLATE EL PS 24V480WDC DC DC STEP UP 12V 24V 480W WEATHER GUARD ...

Page 71: ...O TOR CONTROLLER 24V FM CT BDCMTBP CATALINA BDC MOTOR ADAPTER FM CT BDCMAD CATALINA BDC MOTOR BASE PLATE EL PS 24V480WDC DC DC STEP UP 12V 24V 480W WEATHER GUARD EL TM 30A6CBFB 30A 6 CIRCUIT BLADE FUSE EL SWT DPDT20IP 20A ROTARY SWITCH DP DT IG PROTECTION EL RL 3 5A24VIP inside 3 5A 24V RELAY IGNITION PROOF EL SWT DPDT20IP 20A ROTARY SWITCH DP DT IG PROTECTION EL MTR 1 5BLC24 1 5HP BRUSHLESS MO TO...

Page 72: ...S 3 4VN 3 4 VINYL HOSE PL HS 5 8VN 5 8 VINYL HOSE PL NLT 1 4LP 1 4 Low Pressure Tube Product Hoses and Tubes Note Hose clamps may be substituted for brass ferrules which require a special crimper Inlet Flush Hose Assembly SUB CT Z HPIBHA PL HS 1 2VN 1 2 VINYL HOSE PL QDC 1 2HBDWV 1 2 HB QUICK DISCT BODY WITH VALVE PL HBA 1 2TX1 2 1 2 TUBE x 1 2 HB ADAPTER Brass ferrules for 1 2 inch hose PL HF 75l...

Page 73: ... EL FP BPLDC824 300 1000 BOOSTER PUMP DC 8 24 Volts PL BHF 3 8TPIEJ 3 8 STEM ELBOW JG PL BHF 3 8TSTJG 3 8 BULKHEAD FITTING JG FT STN 6 6 SEA STRAINER ASSY FT STN 6S STRAINER SCREEN PL HBS 3 4X3 4 3 4 HOSE BARB NYL PL CKV 1M3 4FWS 3 4 CHECK VALVE SO STN 6SS SEA STRAINER GASKET Fresh Water Flush Module or Z Ion Boost Pump Module PL BSH 1x1 2N 1 NPT x 1 2 NPT hex bushing reducer Fresh water flush mod...

Page 74: ...c Coupling Body PL QDC HB5 8 5 8 Quick Disc Fitting Hose Barb Brine Discharge Quick Connect High Pressure Fittings PL MTE 3 4S1 2B 3 4 16 ST X 1 2 Tube Fitting Elbow Bronze EL MPC SP4 SALINITY PROBE EL SSR IFM INLINE FLOW METER 0 5 5 L M PL MTE 1 4x3 8J 1 4 x3 8 TUBE FITT ELBOW PL UNN 3 81 4N REDUCING COUPING PL SLN 1 4D12M DIVERSION VALVE SOLENOID PL MNF DVMBK1P DIVERSION VALVE MANIFOLD PL MTE 1 ...

Page 75: ...75 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB10 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used ...

Page 76: ...76 HD CPS 5 162 75 SO HPP SP HP TB VSP HP TB SR SO HPP VB SO HPP PLP SO HPP VP HD CPS 5 16X3 KIT HP 10VSA HP TB ARP SO HPP AR1 SO HPP RV HP TB BV 89 ...

Page 77: ...77 Parts 1 SO HPP PR10 ...

Page 78: ...78 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...