General Pump Troubleshooting Problems

Flash Rate LED “Error” Light

Error Description

Cause

1 Flash

Microprocessor failure

Microprocessor Start-Up

2 Flashes

Low voltage

Voltage must exceed < 208V AC control 
activates itself independently when voltage 

exceeds 208V for more than six (6) seconds 
(Motor Activates)

3 Flashes

Temperature to high

Temperature to low

Temperature Too High > 100

o

 C (212

o

 F)

Temperature Too Low < -20

o

 C (4

o

 F)

4 Flashes

Thermal overload tripped

Motor is drawing to much current/amps

5 Flashes

High voltage

Voltage has risen > 269V AC

6 Flashes

Shaft locked

Impeller or pump locked/motor shaft stopped 
turning

7 Flashes

Self-test

One or more self-test were not completed

8 Flashes

Motor Error

One or more phases is disconnected

Table 2.0
The Badu EcoM3 Warning Sequence

Problem

Possible Cause

Solution

1. Error Light appears during start-up

A. Low Voltage

During the initial start-up (6-12 sec

-

onds delay) or momentary power drop, 

in which case the pump will restart 
itself after the voltage is above 208V 
for a period of six seconds.

2. Pump will not prime.

A. Suction air leak 

B. No water in pump.

C. Closed valves or blocked lines.

D. Low voltage to motor.

Make sure see-through lid and o-rings 
are clean and properly positioned. 
Hand tighten see-through lid. Tighten 

all pipes and fittings on suction side 

of pump. Be sure water in pool is high 

enough to flow through skimmer.

Make sure strainer tank is full of water.

Open all valves in system. Clean skim-
mer and strainer tank. Open pump and 
check for clogging of impeller.

Check voltage at motor. If low, pump 
will not come up to speed.

3. Motor does not turn

A. No power to motor.

B. Pump jammed

Check that all power switches are 
on. Be sure fuse or circuit breaker is 
properly set. Time set properly? Check 
motor wiring at terminal.

With power off, turn shaft. It should 
spin freely. If not, disassemble and 
repair.

4. Low flow

A. Dirty filter

B. Suction Leak

Back wash filter when filter pressure is 

high, or clean cartridges.
See Problem 2

Table 2.0
The Badu EcoM3 General Problems

Summary of Contents for Badu EcoM3

Page 1: ...Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Web site www usa speck pumps com 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notic...

Page 3: ...llation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 4 Operation 12 5 Service and Maintenance 13 Routine Maintenance 13 Winterizin...

Page 4: ...n or disembowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose The following guidelines provide information for pump installation th...

Page 5: ...ly blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas...

Page 6: ...electrical shock do not use extension cord to connect unit to electrical supply provide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cord CAUTION This pump...

Page 7: ...s per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 w...

Page 8: ...ure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings great...

Page 9: ...es must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and dischar...

Page 10: ...easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the excepti...

Page 11: ...e operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the m...

Page 12: ...cially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and tur...

Page 13: ...tes it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Careful...

Page 14: ...ion in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do...

Page 15: ...delay or momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Clos...

Page 16: ...2920723101 1 IMPELLER II 1 0 HP S F 1 0 101 9 0mm M10 2920143310 433 1 MECHANICAL SEAL 14mm 2921141222 412 2 1 O RING CASING 190 x 6mm 2921116125 161 2 1 SEAL HOUSING 14mm 2921111300 113 1 FLANGE 5879...

Page 17: ...hich vary from state to state The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warr...

Page 18: ...2999999978 Rev 03 2010 v1...

Reviews: