The Badu EcoM3 swimming pool pump is both environment friendly and cost efficient. This revolutionary 

three speed pump provides the pool owner a simple three button control to operate the pump, greatly 
reducing the operating cost at a reasonable investment. The robust pump is based on Speck Pumps 

energy efficient design platform. The Badu EcoM3 high performance, medium head pump uses a state 
of  the  art  axial  flux  permanent  magnet  brushless-DC  motor  controlled  by  advance  logic  electronics. 
Providing cooler and quieter operation at a fraction of the cost of a standard PSC motor. The affinity 

laws of hydraulics states that if you halve the speed, the power reduces by 8 times. The multiple speeds 
offered by the Badu EcoM3 enables it to run slower and consume less energy but still have the ability to 
run at full speed if required. 

The Badu EcoM3 operates at a maximum system flow of 100 gallons per minute (GPM).

This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600, 2600, and 3450 RPM. 
This allows you to select the most appropriate speed for your application. The Badu EcoM3 was designed 
to meet the needs of today’s more environmentally friendly consumer. The  pump parts are made of 100% 

recyclable “environment friendly“ plastic. The axial flux brushless-DC motor, has a significant reduction 

in greenhouse gas emissions. Saving greater than 2 tonne CO

2

 per year. Lower noise reduction, and 

energy savings per year. 

Figure 1

The Badu EcoM3 control panel provides manual speed con-
trols for the pump. There are three preset speed buttons that 
can be selected low, medium, and high. 

Controls and LEDs 
1. low, med, and high button/LED: Press one of the buttons 
to select the desired preset pump speed. The pump preset 

speeds are: low (1600 RPM), med (2600 RPM), and high 
(3450 RPM). The button green LED is on when the selected 

button is pressed.
2. Power LED: This green LED light is on when the Badu 
EcoM3 pump is powered up.
3. Error LED: This red LED is on whenever an error has oc-
curred. 

General Description

Summary of Contents for Badu EcoM3

Page 1: ...Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Web site www usa speck pumps com 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notic...

Page 3: ...llation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 4 Operation 12 5 Service and Maintenance 13 Routine Maintenance 13 Winterizin...

Page 4: ...n or disembowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose The following guidelines provide information for pump installation th...

Page 5: ...ly blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas...

Page 6: ...electrical shock do not use extension cord to connect unit to electrical supply provide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cord CAUTION This pump...

Page 7: ...s per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 w...

Page 8: ...ure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings great...

Page 9: ...es must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and dischar...

Page 10: ...easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the excepti...

Page 11: ...e operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the m...

Page 12: ...cially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and tur...

Page 13: ...tes it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Careful...

Page 14: ...ion in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do...

Page 15: ...delay or momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Clos...

Page 16: ...2920723101 1 IMPELLER II 1 0 HP S F 1 0 101 9 0mm M10 2920143310 433 1 MECHANICAL SEAL 14mm 2921141222 412 2 1 O RING CASING 190 x 6mm 2921116125 161 2 1 SEAL HOUSING 14mm 2921111300 113 1 FLANGE 5879...

Page 17: ...hich vary from state to state The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warr...

Page 18: ...2999999978 Rev 03 2010 v1...