background image

4

Important Notice:

This manual contains important information about the installation, operation and safe use of this product. 
This information should be given to the owner and/or operator of this equipment. 

WARNING: 

Before  Installing  this  product,  read  and  follow  all  warning  notices  and  instructions  which 

are  included.  Failure  to  follow  safety  warnings  and  instructions  can  result  in  severe  injury,  death,  or 
property damage. Call 1-800-223-8538 or visit www.usa.speck-pumps.com for additional copies of these 
instructions.

SUCTION  HAZARD.

  Can  cause  serious  injury  or  death.  Do  not  use 

this pump for wading pools, shallow pools, or spas containing bottom 
drains, unless pump is connected to at least two (2) functioning suction 
outlets. 

WARNING:

  Pump  suction  is  hazardous  and  can  trap  and  drown  or 

disembowel bathers. Do not use or operate swimming pools, spas, or 
hot tubs if a suction outlet cover is missing, broken, or loose.

The following guidelines provide information for pump installation 
that  minimizes  risk  of  injury  to  users  of  pools,  spas,  and  hot 
tubs:

Entrapment  Protection:

  The  pump  suction  system  must  provide 

protection against the hazards of suction entrapment.

Suction Outlet Covers:

 All suction outlets must have correctly installed, 

screw-fastened covers in place. All suction outlet (drain) covers must be 

maintained. Drain covers must be listed/certified to the latest published 

edition  of ANSI/ASME A112.19.8.  They  must  be  replaced  if  cracked, 
broken, or missing. 

Number  of  Suction  Outlets  Per  Pump:

  Provide  at  least  two  (2)  

hydraulically-balanced main drains, with covers, as suction for each

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

READ AND FOLLOW ALL INSTRUCTIONS!

DANGER: DO NOT BLOCK SUCTION

WARNING - Entrapment Prevention

Important Safety Instructions

Summary of Contents for Badu EcoM3

Page 1: ...Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Web site www usa speck pumps com 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notic...

Page 3: ...llation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 4 Operation 12 5 Service and Maintenance 13 Routine Maintenance 13 Winterizin...

Page 4: ...n or disembowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose The following guidelines provide information for pump installation th...

Page 5: ...ly blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas...

Page 6: ...electrical shock do not use extension cord to connect unit to electrical supply provide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cord CAUTION This pump...

Page 7: ...s per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 w...

Page 8: ...ure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings great...

Page 9: ...es must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and dischar...

Page 10: ...easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the excepti...

Page 11: ...e operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the m...

Page 12: ...cially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and tur...

Page 13: ...tes it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Careful...

Page 14: ...ion in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do...

Page 15: ...delay or momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Clos...

Page 16: ...2920723101 1 IMPELLER II 1 0 HP S F 1 0 101 9 0mm M10 2920143310 433 1 MECHANICAL SEAL 14mm 2921141222 412 2 1 O RING CASING 190 x 6mm 2921116125 161 2 1 SEAL HOUSING 14mm 2921111300 113 1 FLANGE 5879...

Page 17: ...hich vary from state to state The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warr...

Page 18: ...2999999978 Rev 03 2010 v1...

Reviews: