Routine Maintenance - continued

Winterizing

CAUTION: The pump must be protected when freezing temperatures are expected. Allowing the 
pump to freeze will cause severe damage and void the warranty.

There are two options when winterizing the pump

Option 1:
1. Drain all the water from the pump, system equipment, and piping.

2. Remove drain plugs. Do not replace plugs. Store the plugs in the empty strainer basket for winter. 

3. Keep the motor covered and dry. 

Option 2:
1. Drain all the water from the pump, system equipment, and piping.

2. Remove the pump and motor from the plumbing and store indoors in a warm and dry location.

Note: When the winter season is over the pump will need to be primed prior to start. Refer to 
Section 4 Operation, Start Up Guide.

CAUTION: DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged 
and the pump will start to leak. If this occurs, the mechanical seal will need to be replaced. ALWAYS 
maintain the proper water level in your pool. Continued operation in this manner could cause a 
loss of pressure, resulting in damage to the pump casing, impeller, and mechanical seal.

6. Replace lid with locking ring. 

Hand-tighten

 the lid to make an air-tight seal. 

Do not use any tools to 

tighten the lid. 

7. Verify that all valves have been returned to the proper position for normal operation. Turn on the 
power to the pump.

Troubleshooting

WARNING: The pump must serviced by a professional service technician qualified in pool/spa 
installation.  The  following  procedures  must  be  followed  exactly.  Improper  installation  and/or 
operation can create dangerous electrical hazards, which can cause high voltage to run through 
the  electrical  system.  This  can  cause  property  damage,  serious  personal  injury,  and/or  death. 
Improper installation and/or operation will void the warranty. 

The Badu EcoM3 warnings are indicated by a flashing LED light on the control panel. If the error light is 
on pay attention to the appropriate number of flash intervals of short or long duration, then shut the pump 

down immediately. For example, if a “Low Voltage” warning occurs, the LED will blink two times, then off, 
then blink two times. This sequence is repeated until the condition is cleared.

Summary of Contents for Badu EcoM3

Page 1: ...Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Web site www usa speck pumps com 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notic...

Page 3: ...llation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 4 Operation 12 5 Service and Maintenance 13 Routine Maintenance 13 Winterizin...

Page 4: ...n or disembowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose The following guidelines provide information for pump installation th...

Page 5: ...ly blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas...

Page 6: ...electrical shock do not use extension cord to connect unit to electrical supply provide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cord CAUTION This pump...

Page 7: ...s per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 w...

Page 8: ...ure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings great...

Page 9: ...es must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and dischar...

Page 10: ...easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the excepti...

Page 11: ...e operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the m...

Page 12: ...cially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and tur...

Page 13: ...tes it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Careful...

Page 14: ...ion in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do...

Page 15: ...delay or momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Clos...

Page 16: ...2920723101 1 IMPELLER II 1 0 HP S F 1 0 101 9 0mm M10 2920143310 433 1 MECHANICAL SEAL 14mm 2921141222 412 2 1 O RING CASING 190 x 6mm 2921116125 161 2 1 SEAL HOUSING 14mm 2921111300 113 1 FLANGE 5879...

Page 17: ...hich vary from state to state The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warr...

Page 18: ...2999999978 Rev 03 2010 v1...

Reviews: