background image

16

Product Specifications

PART NUMBER  DRAWING NUMBER 

QTY 

DESCRIPTION

2921116010 

160.1 

LID 

2921116020 

160.2 

LOCK RING - LID 

2901141201 

412.1 

O-RING - LID 137 x 5mm 

2901114300 

143 

BASKET - ONE PIECE 

2921110108 

101 

CASING 

2901158200 

582 

CAP - DRAIN (3/8”) WITH GASKET - CASING 

2920889410 

894.1 

LEGO SPACER 

2920889420 

595 

GASKET - (1/4” x 7/16” x 1”)  

2991000088 

914.1 

SCREW - CASING  HEX/SLOT M7 x 48mm SS 

2920141210 

412.5 

O-RING - DIFFUSER 90 x 5mm 

2921117412 

174.2 

230 

DIFFUSER 

2920723101 

 

IMPELLER (II)    1.0 HP    S.F. 1.0     101 / 9.0mm   M10 

2920143310 

433 

MECHANICAL SEAL (14mm) 

2921141222 

412.2 

O-RING - CASING 190 x 6mm 

2921116125 

161.2 

SEAL HOUSING  14mm                              

2921111300 

113 

FLANGE                                           

5879120825 

914.2 

BOLT - FLANGE  M8 x 25mm 

2991000062 

554.2 

WASHER - FLANGE BOLT (M8)    

2500300902 

721 

SET - DISCHARGE UNION COMPLETE 

2921770001 

721.1 

SET - SUCTION UNION COMPLETE 

2921157700

25 

SPANNER - LID (OPTIONAL) 

2921150700 

507 

SLINGER - SPLASH RING 

2500300914 

721 & 721.1 

COMPLETE UNION SET - SUCTION/DISCHARGE 

7

0

5

0

0

8

1

.

4

1

9

5

9

5

3

3

4

2

.

2

1

4

2

.

4

7

1

2

.

4

1

9

1

.

0

6

1

2

.

0

6

1

3

1

1

2

.

4

5

5

2

.

1

6

1

5

.

2

1

4

0

3

2

1

.

4

5

5

1

.

0

2

9

3

4

1

1

0

1

721

721.1

2

8

5

1

.

2

1

4

1

.

4

9

8

25

Summary of Contents for Badu EcoM3

Page 1: ...Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Web site www usa speck pumps com 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notic...

Page 3: ...llation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 4 Operation 12 5 Service and Maintenance 13 Routine Maintenance 13 Winterizin...

Page 4: ...n or disembowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose The following guidelines provide information for pump installation th...

Page 5: ...ly blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas...

Page 6: ...electrical shock do not use extension cord to connect unit to electrical supply provide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cord CAUTION This pump...

Page 7: ...s per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 w...

Page 8: ...ure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings great...

Page 9: ...es must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and dischar...

Page 10: ...easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the excepti...

Page 11: ...e operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the m...

Page 12: ...cially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and tur...

Page 13: ...tes it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Careful...

Page 14: ...ion in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do...

Page 15: ...delay or momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Clos...

Page 16: ...2920723101 1 IMPELLER II 1 0 HP S F 1 0 101 9 0mm M10 2920143310 433 1 MECHANICAL SEAL 14mm 2921141222 412 2 1 O RING CASING 190 x 6mm 2921116125 161 2 1 SEAL HOUSING 14mm 2921111300 113 1 FLANGE 5879...

Page 17: ...hich vary from state to state The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warr...

Page 18: ...2999999978 Rev 03 2010 v1...

Reviews: