background image

12

Pressure Test - continued

CAUTION: Never run the pump without water. Running the pump “dry“ for any length of time can 
cause severe damage to both the pump and the motor and will void the warranty.

If this is a new pool installation, make sure all piping is clear of construction debris and has been properly 

pressure tested. The filter should be checked for proper installation, verifying that all connections and 

clamps are secure according to the manufacturer’s recommendations.

WARNING: To avoid risk of property damage, severe personal injury or death, verify that all power 
is turned off before starting this procedure.

1. Release all pressure from the system and open the filter pressure release valve.

2. Depending on the location of the pump, do one of the following:

- If the pump is located below the water level of the pool, open the filter pressure valve to prime  the pump 

with water.

- If the pump is located above the water level of the pool, remove the lid and fill the basket with water 

before starting the pump. 

DO NOT run the pump without the basket.

3. Make sure pump turns freely, especially after extended periods of down time. 

Note: To turn the shaft 

place a screwdriver into the slot at the fan end and turn it by in the direction of rotation. If necessary 
remove the fan cover and turn the fan by hand. After re-starting make sure the mechanical seal does not 
leak.

 

4. Prior to replacing the lid, check for debris around the lid o-rings seat. Debris around the lid o-ring seat 

will make it difficult to prime the pump.

5.

 Hand-tighten

 the lid to make an air tight seal. Do not use any tools to tighten the lid: 

hand-tighten 

only.

 Make sure all valves are open and the unions are tight.

WARNING: When pressure testing the system with water, it is very important to make sure that 
the pump basket and lid is completely secure. 

STEPS:
1. Fill the system with water, using care to eliminate trapped air. 

2. Pressurize the system with water to no more than 35 PSI.

WARNING: Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool 
professional. Circulation equipment that is not tested properly might fail, which would result in 
severe injury or property damage. 

3. Close the valve to trap pressurized water in the system.

4. Observe the system for leaks and/or pressure decay.

5. If there are leaks, repeat Steps 1 -3. For technical support, call 1-800-223-8538.

Operation

Summary of Contents for Badu EcoM3

Page 1: ...Installation Operating and Service Manual Badu EcoM3 Swimming Pool Pump...

Page 2: ...ll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Web site www usa speck pumps com 2010 All Rights Reserved Speck Pumps Jacksonville Florida USA This document is subject to change without notic...

Page 3: ...llation 9 Bonding and Grounding 10 Electrical Wiring 10 Setting Up Remote Control 11 Voltage Checks 11 Pressure Testing 11 4 Operation 12 5 Service and Maintenance 13 Routine Maintenance 13 Winterizin...

Page 4: ...n or disembowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or loose The following guidelines provide information for pump installation th...

Page 5: ...ly blocked The flow through the remaining main drain s must comply with the latest published edition of ANSI ASME A112 19 8 the standard for Suction Fittings For Use in Swimming and Wading Pools Spas...

Page 6: ...electrical shock do not use extension cord to connect unit to electrical supply provide a properly located outlet For swimming pool pumps with or without a maximum 3 foot 0 91 m cord CAUTION This pump...

Page 7: ...s per minute GPM This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600 2600 and 3450 RPM This allows you to select the most appropriate speed for your application The Badu EcoM3 w...

Page 8: ...ure to confirm that it will continue to safely operate when the check valves are installed 2 The piping should be as direct and free from turns or bends as possible as elbows and others fittings great...

Page 9: ...es must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing The Badu EcoM3 comes equipped with unions on both the suction and dischar...

Page 10: ...easily turned off CAUTION The pump must be permanently connected to a dedicated electrical circuit No other equipment lights appliances or outlets may be connected to the pump circuit with the excepti...

Page 11: ...e operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS Setting up the remote control The Badu EcoM3 consists of an operator control panel and the system electronics that drive the m...

Page 12: ...cially after extended periods of down time Note To turn the shaft place a screwdriver into the slot at the fan end and turn it by in the direction of rotation If necessary remove the fan cover and tur...

Page 13: ...tes it will begin to block the flow of water through the pump Keep the basket clean and clear to improve the performance of the pump 4 Turn the lid s lock ring counter clockwise until it stops Careful...

Page 14: ...ion in this manner could cause a loss of pressure resulting in damage to the pump casing impeller and mechanical seal 6 Replace lid with locking ring Hand tighten the lid to make an air tight seal Do...

Page 15: ...delay or momentary power drop in which case the pump will restart itself after the voltage is above 208V for a period of six seconds 2 Pump will not prime A Suction air leak B No water in pump C Clos...

Page 16: ...2920723101 1 IMPELLER II 1 0 HP S F 1 0 101 9 0mm M10 2920143310 433 1 MECHANICAL SEAL 14mm 2921141222 412 2 1 O RING CASING 190 x 6mm 2921116125 161 2 1 SEAL HOUSING 14mm 2921111300 113 1 FLANGE 5879...

Page 17: ...hich vary from state to state The manufacturer supplies a limited warranty to the original consumer purchaser of the pump and motor on the following terms and condi tions 1 The pump and motor are warr...

Page 18: ...2999999978 Rev 03 2010 v1...

Reviews: