background image

ASIN

 Salt

ELECTROLYSER FOR DISINFECTION

OF THE SWIMMING POOL WATER

2021

EN

www.asekopool.com

USER MANUAL

Electrode TE–25

www.welldana.com

Summary of Contents for welldana ASIN Salt

Page 1: ...ASIN Salt ELECTROLYSER FOR DISINFECTION OF THE SWIMMING POOL WATER 2021 EN www asekopool com USER MANUAL Electrode TE 25 OF THE SWIMMING POOL WATER Electrode TE 25 www welldana com ...

Page 2: ... of chemical agents Potential consequence Injury heavy material damage Design your installation such that uncontrolled dosage is not possible in the event of a probe failure or other errors and or such that uncontrolled dosage is recognized and halted before damage is incurred Uncontrolled overdose of chemicals can cause harm to health and property Even though the device contains a number of secur...

Page 3: ... is wrong If disinfection is enabled before the pH value is stable in the ideal range of 7 0 to 7 4 then it may lead to heavy overdosing of chlorine or bromine Potential consequence Injury heavy material damage Do not start disinfection with chlorine until the pH value is stable in the ideal range between 7 0 and 7 4 Conditions before using Make sure you have a newest and updated version of the us...

Page 4: ...ing of interconnecting hose of interconnecting hose Dowels and screws Device ASIN Salt Electrode TE 25 Water valves 2 pcs 12006 PE Tube 1 4 6 35 mm transparent 10m 12008 Biocid certified Salt 12110 12110 Inserting plug DN50 Inserting plug DN50 1 4 threaded 12134 Flowmeter with filter 12106 ...

Page 5: ...of chlorine which remains in the the water is broken down with the formation of chlorine which remains in the water in the form of hypochlorous acid ASIN Salt consists of the electrolysis water in the form of hypochlorous acid ASIN Salt consists of the electrolysis cell and the ASIN Salt control unit which cell and the ASIN Salt control unit which Enables the setting of the power in the range 10 1...

Page 6: ...sunlight high humidity and dust can damage ASIN Salt ASIN Salt 40 C max 5 C min 18 5 cm ASIN Salt Electrode TE 25 Wall bracket Flowmeter with filter Flowmeter with filter and salinity measurement Assembly of the Electrode TE 25 The Electrode TE 25 is installed on the outlet water pipeline from the filtration in the swimming pool Assembly is carried out in the direct part of the pipe d 50 by gluing...

Page 7: ...EN 7 50 84 184 mm 50 mm Ø 50 mm 13 mm 20 Nm ASIN Salt Besgo Salinity sensor is now in the filter Max 1 5 m Gluing TO POOL Heating FROM POOL FROM POOL FROM POOL ...

Page 8: ...or and then lock it by pulling back To disconnect the interconnecting tube push and hold a circular collet and pull the interconnecting tube out WARNING To treat PE tube ends use a sharp knife part of delivery The use of scissors or tongs deforms the tube end and leads to leaks WARNING Only hand tighten Do not use tongs or any other tools 1 To ensure tightness of joints cut the tube at 90 angle Us...

Page 9: ...ASIN Salt THE WATER OUTLET POOL WATER INLET WATER INLET IN IN OUT OUT OUT Salinity sensor is now in the filter Water cooled Besgo TO POOL Heating FROM POOL FROM POOL FROM POOL Max pool water pressure 1 5 Bar ...

Page 10: ...PÁJENÍ 230 V 50 Hz Besgo 3 W Dnová výpust 30 31 Besgo 5 W Praní filtru Solenoid dopuštění 32 33 34 35 26 27 28 29 36 37 38 39 40 Timer Bottom B wash Filling Heating 230 V 50 Hz T1A Pumpe N Ext out In 15V T fuse L N L N L T fuse T fuse T fuse T fuse 10 10 10 10 10 11 11 11 11 11 RS 485 Display RS 485 Display RS 485 Display RS 485 Display RS 485 Display RS 485 Display RS 485 Display RS 485 Display R...

Page 11: ...EN 11 Connection cable to ASIN Salt TE 25 ASIN Salt TE 25 ASIN Salt TE 25 ASIN AQUA Salt TE 25 ASIN AQUA Salt HEATING TO POOL FROM POOL FROM POOL up to 10 modules Select the EXT mode ...

Page 12: ...ion 2 Disconnect the ASIN Salt mains cable from the 230 V 50 Hz socket outlet WARNING If Device is used in the manner different from that specified by the manufacturer protection provided by Device may get damaged Power supply 230 V AC 50 Hz Power consumption 157 W Unit fuse T2A Electronics fuse T125 mA Protection class IP30 Overvoltage category II Operation temperature 5 to 40 C Max measuring wat...

Page 13: ...cal current flow through the electrodes The auto mode changes the direction of the current flow automatically after 1 hour This mode is suitable for water with a higher hardness A longer service life of the electrode can be achieved by lengthening the reversal time so that one of the two current flow directions can also be permanently set This mode is only suitable for waters with a low mineral co...

Page 14: ...ncentration before switching the power supply again Never use lower salt concentration than 3g l this expressively reduce the electrode lifetime Higher salt concentration is very corrosive and may cause corrosion of pool equipment Disinfection is expressively affected by following temperature intensity of sun shining quantity of person using the pool weather conditions organic pollution Instructio...

Page 15: ...3 50 m3 60 m3 70 m3 Salt quantity in kg necessary to increase the concentration to 4 kg m3 0 40 60 80 100 120 140 160 200 240 280 0 25 37 5 56 25 75 93 75 112 5 131 25 150 187 5 225 262 5 0 5 35 52 5 70 87 5 105 122 5 140 175 210 245 0 75 32 5 48 75 65 81 25 97 5 113 75 130 162 5 195 227 5 1 30 45 60 75 90 105 120 150 180 210 1 25 27 5 41 25 55 68 75 82 5 96 25 110 137 5 165 192 5 1 5 25 37 5 50 6...

Page 16: ...ing parameters Low salt content Water temperature below 10 C Low water flow Too hard water pH below 7 5 Addition of metals containing preparations Electrolysis cell cleaning Electrolysis cell cleaning In operation the electrolysis cell is gradually clogged by sediments from the hard water that must be eliminated repeatedly The clogging of the electrolysis cell decreases the electrolysis cell capac...

Page 17: ...EN 17 ...

Page 18: ...EN 18 ...

Page 19: ...EN 19 ...

Page 20: ...www asekopool com ASIN Salt USER MANUAL EN www welldana com ...