MAXITROL GV60 CONTROL SYSTEM
Set Temp 74°F
Set Temp 40°F
Set Temp 74°F
Set Temp 40°F
Timer Programming Example
(default temper atures shown)
6:00 a.m.—P1
Start time
☼
☼
8:00 a.m.—P1
End time
4:00 p.m.—P2
Start time
10:00 p.m.—P2
End time
6:00 a.m.—P1
Start time
No communication.
If there is no communication between the receiver and the handset for a
period of 6 hours, the appliance goes into pilot mode.
No change in ame height.
If there is no change in flame height for a period of 6 hours, the ap-
pliance goes into pilot mode.
NOTE:
In
TEMP
or
TIMER
modes, the flame height will vary according to room temperature.
The appliance will continue to work normally. However, if the room temperature remains the same
for 6 hours, the appliance will go into pilot mode.
Low batteries in the receiver.
With low
battery power in the receiver the system shuts off completely.
NOTE:
This does not apply when the power supply is interrupted.
No change in pilot.
The appliance shuts off completely when it is continually in pilot position—
without any change—for a period of 5 days.
AUTOMATIC TURN DOWN
AUTOMATIC SHUT OFF
LOW BATTERY INDICATION
DO NOT USE
a screwdriver or other metallic
object to remove the batteries from the battery box
or the handset! This could cause a short circuit.
CAUTION
Remote handset:
The battery icon
will show when the battery needs to be replaced.
Replace with one
3 “
AAA
”
alkaline
batteries.
Receiver:
Three short
‘
beeps
’
will sound when the motor turns when the batteries need to be re-
placed. Replace with four 1.5 V
alkaline
batteries.
HANDSET / RECEIVER MATCH
The remote control handset and receiver are program- med to function together. In case of a re-
placement of the handset or the receiver, you will need to reset the receiver to allow them to func-
tion together. Contact your dealer for details.