ASSEMBLY
Installing the Fireplace Surround with Integrated Screen
The decorative surround with integrated screen for the fireplace is held in place by four brackets. Two are
located on the top of the fireplace and two on the bottom. There are mating brackets and catch plates on the
surround itself. Refer to the adjacent illustrations when installing the surround.
1. Unpack the surround with integrated screen from
shipping box.
2. With a helper, lift the surround with integrated
screen up and identify the top by looking for the
vertical brackets that are visible from the rear of the
surround.
3. Move the surround with integrated screen into
place, generally centering the surround opening
over the glass panel. Keep the bottom of the sur-
round tipped slightly away from the fireplace.
4. While looking behind the surround with integrated
screen, guide the two surround brackets onto the
forward detent of the mating brackets on the fire-
place top. You might find it easier to engage one
bracket and then the other. Lower the surround until
both bracket sets are fully mated.
5. Carefully push the top of the surround with inte-
grated screen so that the surround brackets slide
into the rear detent of the mating brackets on the
fireplace top.
6. Carefully swing the bottom of the surround with integrated screen toward the base of the fireplace until
the catch plates on the bottom flange of the surround with integrated screen are aligned with the spring
loaded plungers on the bottom flanges of the lower surround mounting brackets.
7. To remove the surround with integrated screen, pull the bottom edge of the surround outward to disen-
gage the spring loaded plungers and then lift the top up and off the upper brackets.
8. To prevent damage to the surround with integrated screen, always set the surround in a safe place while
it is removed from the fireplace.
UPPER SURROUND BRACKETS
WHEN PROPERLY MATED
CATCH
PLATE