MAXITROL GV60 CONTROL SYSTEM
Press and hold (small
flame) button to decrease
flame height or to set the ap-
pliance at pilot flame.
For fine adjustment tap the
(large flame) or (small
flame) buttons.
MODES OF OPERATION
Express Low and High Fire
Double-click (small flame)
button.
“
LO
”
will be displayed.
NOTE: Flame goes to high fire
first before going to designated
low fire.
Double-click
(large flame)
button. Flame automatically
goes to high fire.
“
HI
”
will be
displayed.
x 2
SETTING °C/24-HOUR OR °F/12-HOUR
In MAN mode, press OFF
and (small flame) buttons
until display changes from
Farenheit/12-hour clock to
Celsius/24-hour clock and
vice versa.
SETTING THE TIME
The time display will flash af-
ter either:
» Installing the battery or
» Simultaneously pressing the
(large flame) and
(small flame) buttons
Press (large flame) button
to set the hour.
Press (small flame) button to
set the minute.
Press OFF or simply wait to return to MAN
mode.
Briefly pressing the SET button
changes the mode of operation in
the following order:
and back to
MAXITROL GV60 CONTROL SYSTEM
NOTE:
Manual mode can also be reached by
pressing either the (large flame) or the
(small flame) buttons.
- Manual Mode -
Man
ual
Flame Height Adjustment.
- Daytime Tempera-
ture Mode
(Appliance must be in
standby mode; pilot ignited)
-
The
room temperature is measured and
compared to the set temperature.
The flame height is then automati-
cally adjusted to achieve the Day-
time Set Temperature.
TEMP
- Nighttime Setback
Temperature Mode
(Appliance
must be in standby mode; pilot ig-
nited)
-
The room temperature is
measured and compared to the
nighttime Setback temperature.
The flame height is then automati-
cally adjusted to achieve the
Nighttime Setback Temperature.
- Timer Mode
(Appliance
must be in standby mode; pilot ignited)
-
The timers P1 and P2 (Program 1, Pro-
gram 2) each can be programmed to go
ON and OFF at specific times. For in-
structions see Timer Programming Mode.
NOTE:
The display shows the set temperature every 30
seconds.