6.Command Specification
SEND DIAGNOSTIC
SONY AIT-3 drive SDX-700 series Ver.2.1
6-100
6.25.
SEND DIAGNOSTIC 1Dh
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (1Dh)
1
Logical Unit Number
PF
Reserved
SelfTest
DevOfl(0)
UnitOfl
2
Reserved
3
(MSB)
Parameter List Length
4
(LSB)
5
Unused (00b)
Reserved
Flag
Link
SEND DIAGNOSTIC tells the drive to perform diagnostic tests on itself.
PF
: The drive expects the Page Format bit to be set to indicate that the parameters transferred during the DATA
OUT phase will include four bytes of header information as well as the diagnostic test bytes.
If this bit is not set the parameter bytes will only describe the diagnostic test. Note that if the SelfTest bit is set, this bit
must be ZERO else the drive will return CHECK CONDITION with the ILLEGAL REQUEST sense key set.
SelfTest
: When this bit is set the drive executes its POWER-ON SEQUENCE. The Parameter List Length must be
ZERO when this bit is set other-wise the drive will return a CHECK CONDITION status with an ILLEGAL REQUEST
sense key set. After Self Test, a LOAD command is required to bring the drive online.
DevOfl
: Device Off-line is not supported and shall be set to ZERO, otherwise the driver will return a CHECK
CONDITION status with an ILLEGAL REQUEST SENSE key set.
UnitOfl
: This bit must be set for proper operation of any diagnostic test except Self Test. If this bit is not set, except
for self-test, the drive will return a CHECK CONDITION status with an ILLEGAL REQUEST sense key set.
Parameter List Length
: This field provides the count of the number of Parameter List bytes which will be transferred
in the DATA OUT phase. These bytes describe the test that is to be run. This field must be set to ZERO if the
Self-Test bit is set.
If the PF bit is ZERO, the Parameter List describes the diagnostic test to be executed. The diagnostic tests are five
bytes in length. If the Parameter List Length is not set to five or ZERO if the Self-Test bit is set , the drive returns a
CHECK CONDITION status with an ILLEGAL REQUEST sense key set.
If the PF bit is set, the Parameter List includes a four byte header as of the form:
Table 6-74: Diagnostic Page Format
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code
1
Reserved
2
(MSB)
Page Length (n-3)
3
(LSB)
Page Code
: The drive supports two Page Codes:
00h - Return Supported pages
81h - Drive Diagnostic page
For Page Code 00h, the Page Length must be ZERO and the Parameter List Length must be set to four otherwise
the drive returns a CHECK CONDITION status with an ILLEGAL REQUEST sense key set. This Page Code
requests that the drive return a list of the supported pages in the DATA IN phase of RECEIVE DIAGNOSTIC.
Summary of Contents for SDX-700C
Page 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Page 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Page 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...