6.Command Specification
READ BLOCK LIMITS
SONY AIT-3 drive SDX-700 series Ver.2.1
6-76
6.13.
READ BLOCK LIMITS 05h
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (05h)
1
Logical Unit Number
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Unused (00b)
Flag
Link
The READ BLOCK LIMITS command tells the drive to return its limits for Block Length. The READ BLOCK LIMITS
data shown below will be sent during the DATA IN phase of the command. The command does not reflect the
currently selected block size, only the available limits. MODE SENSE returns the current block size. 2 bytes is the
minimum and 16 Mbytes - 1 byte is the maximum block size which the unit can support.
Note
: The SDX-700C supports one byte variable Read commands. However one byte Write operations are not
supported and will be rejected with a CHECK CONDITION for ILLEGAL REQUEST.
Table 6-57: READ BLOCK LIMITS Data
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
1
(MSB)
2
Maximum Block Length Limit (FF FF FFh)
3
(LSB)
4
(MSB)
Minimum Block Length Limit (00 02h)
5
(LSB)
Summary of Contents for SDX-700C
Page 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Page 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Page 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...