3.Installation
SONY AIT-3 drive SDX-700 series Ver.2.1
3-3
DC Control-1
DC Control-2
Definition
OFF
OFF
Compression disabled at power-on. The host is allowed to control
compression.
OFF
ON
Compression disabled at power-on. The host is not allowed to control
compression.
ON
OFF
Compression enabled at power-on. The host is allowed to control
compression.
ON
ON
Compression enabled at power-on. The host is not allowed to control
compression.
Figure 3-4: Data Compression Switches
3.1.5.
Power Connector
The power connector is illustrated as Figure 3-5.
5V GND GND 12V
4 3 2 1
Figure 3-5: Power Connector
3.1.6.
SCSI 68 pin Connector
Figure 3-6 illustrates SCSI 68 pin connector, and table 3-1 shows the assignments for the pins of the connector.
Pin 34 1
Pin 68 35
Figure 3-6: Non-shielded SCSI Device Connector
SDX-700C supports both Low-Voltage-Differential SCSI configuration as shown table 3-1 and Single-Ended SCSI
configuration as shown table 3-2. SDX-700C detects and switches SCSI configuration between
Low-Voltage-Differential and single-ended modes by monitoring DIFSENS signal assigned pin 16 in SCSI bus.(refer
to table 3-1)
Summary of Contents for SDX-700C
Page 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Page 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Page 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...