6.Command Specification
MODE SELECT
6-50
SONY AIT-3 drive SDX-700 series Ver.2.1
Single Partition Tape
BOM BOT
Partition 0
EOP/EOM
Two Partition Tape
Partition 1
BOM
Device
Area
System
Area
User Data Area
End of
Data
BOT
Partition 0
EOP/EOM
Device
Area
System
Area
User Data Area
End of
Data
User Data Area
System
Area
End of
Data
EOT
EOT
EOT
BOM = Beginning-of-Media (Physical)
BOT = Beginning-of-Tape (Logical)
EOM = End-of-Media (Physical)
EOP = End-of-Partition (Logical)
EOT = End-of-Tape (Logical)
Figure 6-1: Tape Partition Layout
The Host may, therefore, partition a tape into one partition which spans the whole physical length of the tape or into
two partitions, each of which will behave as completely separate and independent tapes.
A tape does not require partitioning prior to use. If a Host only wishes to use a single partition tape, then there is no
need to send this page. On the first WRITE to a blank tape, the device will create the System, Reference and
Vendor areas on tape before proceeding with the write. To reformat from a two to a single, or from a single to a two
partition tape, the Host is required to use the Medium Partitions Parameter page.
PSUM
: The Partition Size Unit of Measured field defines the units in which the Partition Size value selects the
partition size, which in the case of this drive is Megabytes. Therefore, the drive returns 10b for a MODE SENSE and
will only accept this value for a MODE SELECT, otherwise a CHECK CONDITION status is returned with an
ILLEGAL REQUEST Sense Key set.
Medium Format Recognition
: This field is only valid on a MODE SENSE and is set to 03h to indicate that the drive
is capable of format and partition recognition. This is non-changeable field. It accepts all the value, however always
returns 03.
Partition Sizes
: This field allows the initiator to allocate the capacity of each partition. It will also allow the initiator to
reallocate the capacity of previously partitioned tapes.
The Partition Size specifies the capacity of all partitions in Megabytes. The drive rounds the Partition Size to the next
whole group value and then applies an algorithm which allows for the writing of ECC-3 frames and for RAW error
recovery so as to reserve sufficient physical space on the media for the specified capacity. The minimum space
allocated shall be 3050 frames.
If the Additional Partitions Defined and Partition Size fields are set to ZERO the drive will initialize the tape as
partition 0, and create a single partitioned tape.
The size of partition 0 is only valid during Mode Sense and is ignored during Mode Select. For Mode Select only
partition 1 size is used when Additional Partitions Defined field is set to 01h. Partition 0 size is ignored. Internally, the
drive computes partition 0 size to be the remaining capacity of the tape. This remaining capacity is the maximum
uncompressed capacity minus partition 1 size.
A second way to issue Mode Select Page 11h is to set Page Length to 08h, and set bytes 8 and 9 to partition 1 size.
In this method partition 0 size is not sent, but this size is still computed as defined above. In either case, Mode Sense
will report partition 0 and partition 1 sizes.
EOP
Summary of Contents for SDX-700C
Page 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Page 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Page 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...