6.Command Specification
LOG SENSE
6-28
SONY AIT-3 drive SDX-700 series Ver.2.1
Table 6-25: Mechanism Error Event Format
Byte offset
Meaning
0
1
2-4
Error code
Executing Mechanism Commands when error was detected
Time-stamp(minute)
Executing Mechanism Commands
Search-Standby
PWM-Drive
Diagnostics
40h
41h
80h
Forward-ATF-On
Spool-Forward
Thread
Un-tension
Reverse
Spool-Reverse
Unthread
Stop
Eject
Still
Forward
Load
Re-tension
Re-start
Pinch-On
Pinch-Of
01h
07h
0Fh
10h
11h
17h
20h
21h
22h
23h
30h
31h
32h
33h
36h
37h
6.6.10. Read and Write Frame Error Counter Page
The Read and Write Error Counter Page has the following format. All fields in these logs are initialized to ZERO in
the following circumstances:
At Power On
After a cassette loading
After a user sends a request for initialization through Log Select
After a SCSI Bus Reset
Following configuration for error rate testing
6-26: Read and Write Frame Error Counter Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code (34h Write Frame Error Counters, 35h Read Frame Error Counters)
1
Reserved
2
(MSB)
Page Length (38h/ 48h)
3
(LSB)
Error Counter Descriptors
Bit
Byte
7 6 5 4 3 2 1 0
0
(MSB) Parameter
Code
1
(LSB)
2
DU(0) DS(1) TSD(0) ETC(0)
TMC(0)
Reserved LP(0)
3
Parameter Length (4)
4
(MSB) Parameter
Value
7
(LSB)
Parameter Code
: This identifies which parameter of data is being transferred. The following codes are supported
for each Error Counter Page.
Summary of Contents for SDX-700C
Page 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Page 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Page 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...