3.Installation
SONY AIT-3 drive SDX-700 series Ver.2.1
3-2
1 Reserved (OFF)
2 Reserved (OFF)
3 Reserved (OFF)
4 Reserved (OFF)
5 Terminator Power (ON)
6 Reserved (OFF)
7 DC Control-1
8 DC Control-2
1 2 3 4 5 6 7 8
ON
OFF
Figure 3-3: DIP Switch positions
3.1.1.
SCSI ID Number Jumper
The SCSI ID number of the SDX-700C is selected by the SCSI ID number jumpers. The figure below shows the
jumper configuration for each of the possible SCSI IDs.
SCSI ID3 ID2 ID1 ID0
0 : : : :
1 : : : |
2 : : | :
3 : : | |
4 : | : :
5 : | : |
6 : | | :
7 : | | |
8 | : : :
9 | : : |
10 | : | :
11 | : | |
12 | | : :
13 | | : |
14 | | | :
15 | | | |
:
= OPEN
Jumper not installed
|
= CLOSED
Jumper installed
3.1.2.
Termination Power Switch
Position 5 of DIP switch is used to set whether SDX-700C provides the termination power to pin 17,18,51,52 on
SCSI bus, or not..
3.1.3.
Parity Disable Jumper
Parity check function can be disabled by Jumper. Parity check is disabled while left end jumper is installed. Parity
generate function is always enabled.
Parity
Setting
Disable
|
Enable
:
:
= OPEN
Jumper not installed
|
= CLOSED
Jumper installed
3.1.4.
Data Compression ON switch
Data compression can be selected by DIP switch.
Summary of Contents for SDX-700C
Page 12: ...1 Introduction SONY AIT 3 drive SDX 700 series Ver 2 1 1 4 This page intentionally left blank ...
Page 28: ...3 Installation SONY AIT 3 drive SDX 700 series Ver 2 1 3 6 This page intentionally left blank ...
Page 178: ...10 Appendix C 10 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 180: ...11 Appendix D 11 2 SONY AIT 3 drive SDX 700 series Ver 2 1 This page intentionally left blank ...
Page 186: ...12 Appendix E SONY AIT 3 drive SDX 700 series Ver 2 1 12 6 This page intentionally left blank ...