PCS-G50/G50P
4-28
4-3. Operation Check in Application
Mode (Normal Operation)
In this Section, the command (written in bold) input from
the terminal PC and the response status are described as
follows.
(Example)
pcsdb> cntr
↓
: Enter “
cntr
” from the terminal PC,
and press the Enter key.
ok
:
Response status for entering “
cntr
”.
4-3-1. Network Interface Check
Check if the network interface is normal. Perform the
check by connecting the network cable from a device, such
as a HUB, to the 100BASE-TX/10BASE-T connector of
the unit.
4-3-2. Initial Setting Check
1.
Refer to Section 4-1-1, and start the terminal software.
2.
Enter the following command from the terminal PC,
and check the response status.
pcsdb> cntr
↓
ok
3.
Enter the following command from the terminal PC,
and check the initial setting of the unit.
status machine
↓
PCS-G50
xxxxxxxxxx
: Serial number
Ver.xx.xx
: HOST version
Ver.xx.xx
: DSP version
xxx.xxx.xxx.xxx
: IP address
xx-xx-xx-xx-xx-xx
: MAC address
optionline-xx
: Option Line (with/without)
optionrgb-xx
: DSB (with/without)
optionh320mcu-xx
: 320MCU Option (with/without)
optionh323mcu-xx
: 323MCU Option (with/without)
optionwb-xx
: White board Option (with/without)
4.
After checking, enter the following command and end
the terminal software.
exit
↓
ok
4-2-8. Video Input Check
1.
Refer to Section 4-1-2, and start the Diag mode.
2.
Refer to steps (1) and (2), and input the color-bar
signal to the VIDEO IN AUX IN connector of the unit.
(1) Connect the unit’s VIDEO IN AUX IN and
VIDEO OUT AUX connectors using the video
cable with a connector (supplied accessary).
(2) Enter the following command from the terminal
PC, and check the response status.
command> cb cenc
↓
Color Bars on VOA( 1, 2 ) CENC screen
3.
Enter the following command from the terminal PC,
and check the response status.
command> videoin 0 2
↓
command> vlpc y 135 330
↓
0xXX
4.
Check that the response status “
0xXX
” is within
specification.
Specification:
0x98
to
0xb6
5.
Enter the following command from the terminal PC,
and check the response status.
command> vlpc b 405 330
↓
0xXX
6.
Check that the response status “
0xXX
” is within
specification.
Specification:
0xa9
to
0xbd
7.
Enter the following command from the terminal PC,
and check the response status.
command> vlpc r 405 330
↓
0xXX
8.
Check that the response status “
0xXX
” is within
specification.
Specification:
0xb7
to
0xcf
9.
After checking, enter the following command from the
terminal PC.
command> videovfp 4 0
↓
command> cb off
↓
command> videoin 0 0
↓
command> videoin 1 0
↓
Summary of Contents for Ipels PCS-G50
Page 6: ......
Page 16: ......
Page 26: ......
Page 34: ......
Page 170: ......
Page 186: ......
Page 191: ...PCS G50 G50P 8 7 8 7 CPU 382 B SIDE SUFFIX 12 13 A B C D 1 2 3 4 CPU 382 CPU 382 ...
Page 198: ......
Page 199: ......
Page 200: ...Printed in Japan Sony Corporation 2005 6 22 2005 PCS G50 UC PCS G50P CE E 9 968 181 01 ...