![Sony HDV HVR-A1U Service Manual Download Page 213](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564213.webp)
6-54
HVR-A1J/A1U/A1N/A1E/A1P/A1C
25. White Defect Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Defect white defective pixels of CMOS image sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6 address: D3 is “00”
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
0D
Check the data is “04”.
3
0
10
06
4
B
41
10
Press PAUSE (Write) button.
(6B)
5
0
10
00
6
6
D0
06
7
6
01
21
Press PAUSE (Write) button.
8
6
02
Check the data changes to
“01”.
9
6
D3
Check the data is “00”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
10
06
3
B
41
10
Press PAUSE (Write) button.
(6B)
4
0
10
00
5
0
01
00
26. White Defect Adjustment (FD white point)
RadarW
RadarW
RadarW
RadarW
RadarW
Defect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Not required
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
0D
Check the data is “04”.
3
0
10
06
4
B
41
02
Press PAUSE (Write) button.
(6B)
5
0
10
00
6
6
D0
0C
7
6
01
21
Press PAUSE (Write) button.
8
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
10
06
3
B
41
10
Press PAUSE (Write) button.
(6B)
4
0
10
00
5
0
01
00