![Sony HDV HVR-A1U Service Manual Download Page 175](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564175.webp)
6-16
HVR-A1J/A1U/A1N/A1E/A1P/A1C
4.
63 Page table
Note 1:
If reading/writing data on pages 63, set data: 06 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 63 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 2C
Fixed data-1 (Initialized data)
2D
Fixed data-2
2E to 3B
Fixed data-1 (Initialized data)
3C
Fixed data-2
3D to 54
Fixed data-1 (Initialized data)
55
Fixed data-2
56 to 5C
Fixed data-1 (Initialized data)
5D
Fixed data-2
5E to 6D
Fixed data-1 (Initialized data)
6E
Fixed data-2
6F to 86
Fixed data-1 (Initialized data)
87
Fixed data-2
88 to 8D
Fixed data-1 (Initialized data)
8E
Fixed data-2
8F to 9A
Fixed data-1 (Initialized data)
9B
9C
Fixed data-2
9D, 9E
Fixed data-1 (Initialized data)
9F
Fixed data-2
A0 to A6
Fixed data-1 (Initialized data)
A7
Fixed data-2
A8 to FF
Fixed data-1 (Initialized data)
3.
F Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00
Fixed data-2
01 to 14
Fixed data-1 (Initialized data)
15
16
Fixed data-2
17 to 8B
Fixed data-1 (Initialized data)
8C
Fixed data-2
8D to 8F
Fixed data-1 (Initialized data)
90
Fixed data-2
91
Fixed data-1 (Initialized data)
92
Fixed data-2
93 to 95
Fixed data-1 (Initialized data)
96
Fixed data-2
97
Fixed data-1 (Initialized data)
98
Fixed data-2
99
Fixed data-1 (Initialized data)
9A
Fixed data-2
9B to A2
Fixed data-1 (Initialized data)
A3
Fixed data-2
A4 to B0
Fixed data-1 (Initialized data)
B1
Fixed data-2
B2 to BA
Fixed data-1 (Initialized data)
BB
Fixed data-2
BC, BD
Fixed data-1 (Initialized data)
BE
Fixed data-2
BF to FF
Fixed data-1 (Initialized data)