![Sony HDV HVR-A1U Service Manual Download Page 189](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564189.webp)
6-30
HVR-A1J/A1U/A1N/A1E/A1P/A1C
3.
MR Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
58, 5A to 65
Specified value 1
40 to C0
Specified value 2
03 to 78
Specified value 3
88 to FD
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment” after this adjustment.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
BD
Press PAUSE (Write) button.
(Note 5)
3
6
02
Check the data changes to
“01”.
4
0
10
06
5
5A
F
5B
(6F)
5C
5D
6
5E
F
60
(6F)
62
64
7
5F
F
61
(6F)
63
65
8
0
10
00
Note 5:
The adjustment data will be automatically input to page:
6F, address: 58, 5A to 65.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
01
00
Press PAUSE (Write) button.
4
0
01
00
Check that the data of each
address satisfied the specified
value 1.
Check that the data of each
address satisfied the specified
value 2.
Check that the data of each
address satisfied the specified
value 3.