![Sony HDV HVR-A1U Service Manual Download Page 197](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564197.webp)
6-38
HVR-A1J/A1U/A1N/A1E/A1P/A1C
12. Auto White Balance Standard Data Input
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (All white frame)
Adjustment Page
6E
Adjustment Address
00 to 0F
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” before this adjustment.
Note 2:
If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data
setting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”
2
0
01
01
3
6
4D
40
4
Wait for 2 seconds.
5
6
01
43
Press PAUSE (Write) button.
6
6
01
41
Press PAUSE (Write) button.
(Note 4)
7
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
6E, address: 00 to 0F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
4D
00
2
6
01
00
Press PAUSE (Write) button.
3
0
01
00
11. Picture Frame Setting (All white frame)
Subject
Clear chart (All white frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V jack (75
Ω
terminated)
Measuring Instrument
Monitor TV
Specified Value
Only the clear chart must be shot
(entire screen is white).
Note:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS ................................................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
6
90
70
3
6
91
02
4
6
92
00
5
6
93
46
6
6
01
79
Press PAUSE (Write) button.
7
Check that the entire screen
is white.
8
In the following adjustment,
if the “All white frame” is
used, adjust the clear chart to
this position.
Processing after Completing Adjustment:
Reset the data setting after the adjustment finished.
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00