![Sony HDV HVR-A1U Service Manual Download Page 193](http://html.mh-extra.com/html/sony/hdv-hvr-a1u/hdv-hvr-a1u_service-manual_1323564193.webp)
6-34
HVR-A1J/A1U/A1N/A1E/A1P/A1C
6.
Flange Back and Zoom Lever Center Adjustment
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
6-1.
Flange Back Adjustment (1)
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 48 to 58
Specified value
Data of page: 6F, address: 57 is
“00” to “09”
Data of pege: 6, address: 0C is “00”
Note 1:
Perform “HALL Adjustment”, “MR Adjustment” and
“Image Sensor Output 2ch Matching Adjustment” be-
fore this adjustment.
Note 2:
Perform the adjustment with the lens in horizontal state.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
4D
40
3
6
64
04
4
0
10
06
5
B
0D
Set the bit value of bit3 is
(6B)
“1”, and press PAUSE
(Write) button. (Note 6)
6
0
10
00
7
6
14
83
8
6
01
13
Press PAUSE (Write) button.
9
Wait for 2 seconds.
10
6
01
15
Press PAUSE (Write) button.
(Note 7)
11
6
02
Check the data changes to
“01”.
12
6
0C
Check the data is “00”.
13
0
10
06
14
F
57
Check the data is “00” to
(6F)
“09”.
15
0
10
00
Note 6:
For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.
Note 7:
The adjustment data will be automatically input to page:
6F, address: 11, 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
01
00
Press PAUSE (Write) button.
4
6
14
00
5
6
4D
00
6
6
64
00
7
0
10
06
8
B
0D
Set the bit value of bit3 is
(6B)
“0”, and press PAUSE
(Write) button. (Note 6)
9
0
10
00
10
0
01
00
11
Perform “Flange Back
Adjustment (2)”.