6-14
HVR-A1J/A1U/A1N/A1E/A1P/A1C
4.
1D Page table
Note 1:
If reading/writing data on pages 1D, set data: 01 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 1D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 2B
Fixed data-1 (Initialized data)
2C
Fixed data-2
2D, 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30 to FF
Fixed data-1 (Initialized data)
1-2-2.
Initialization of 9, 1D Page Data
1.
Initializing of 9, 1D Page Data
Note1:
If “Initialization of Pages 9, 1D” is executed, all data on
pages 9, 1D are initialized. (Only an individual page can-
not be initialized)
Note2 :
If the 9, 1D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of 9, 1D page data
Adjustment Page
9
Adjustment Address
10 to FF
Adjustment Page
1D
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
81
00
4
3
80
04
Press PAUSE (Write) button.
Check the data changes to
5
3
80
“14”.
Perform “Modification of 9,
6
1D Page Data”
2.
Modification of 9, 1D Page Data
If the 9, 1D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 9, set data: 00 to page: 0,
address: 10, and then select pages 9.
3) If modification of data on pages 1D, set data: 01 to page: 0,
address: 10, and then select pages D.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 9, 1D page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
3.
9 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to FF
Fixed data-1 (Initialized data)