6-39
HVR-A1J/A1U/A1N/A1E/A1P/A1C
13. LV Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Subject
Clear chart (All white frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
2A, 2B
Specified Value
0FE0 to 1020
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”
2
0
01
01
3
6
4D
40
4
6
C9
10
5
Wait for 6 seconds.
6
6
01
0D
Press PAUSE (Write) button.
(Note 5)
7
6
02
Check the data changes to
“01”.
8
0
03
1E
9
1
Check that the displayed data
(Note 4) satisfied the
specified value.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
4D
00
2
6
C9
00
3
6
01
00
Press PAUSE (Write) button.
4
0
03
00
5
0
01
00