— 4 —
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Before change
After change
6. ADJUSTMENT
6-1. CAMERA SECTION ADJUSTMENT
• Change of EVR Page Table
-
: Points changed portion
1-2.
INITIALIZATION OF EVR DATA
1-2-2.
Initialization of 8, 9, C, 13, 18, 1C, 1D, 1E
Page Data
10. 1E Page table
Address
Initial value
Remark
NTSC PAL
00 to 83
Fixed data-1 (Initialized data)
84, 85
Fixed data-2
86 to FF
Fixed data-1 (Initialized data)
1-2.
INITIALIZATION OF EVR DATA
1-2-2.
Initialization of 8, 9, C, 13, 18, 1C, 1D, 1E
Page Data
10. 1E Page table
Address
Initial value
Remark
NTSC PAL
00 to 53
Fixed data-1 (Initialized data)
54
Fixed data-2
55 to 83
Fixed data-1 (Initialized data)
84, 85
Fixed data-2
86 to FF
Fixed data-1 (Initialized data)
• Change of Flange Back Adjustment
&
: Points added portion
-
: Points changed portion
1-3.
CAMERA SYSTEM ADJUSTMENTS
1-3-1. Camera System Adjustments
7.
Flange Back Adjustment
7-1.
Flange Back Adjustment
(Service manual page 6-28)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
BF
19
AA
3
BF
90
80
4
6
61
01
5
Wait for 3 seconds.
6
0
10
09
7
F
4A
83
(9F)
8
F
4B
80
(Note 10)
(9F)
9
0
10
00
10
6
02
Check the data is “00”.
11
6
99
Check the data is “00”.
12
6
4D
40
13
6
64
04
14
0
10
07
15
E
10
Set the bit value of bit1 is “0”,
(7E)
and press PAUSE (Write)
button. (Note 8)
16
0
10
00
17
6
40
01
18
6
01
13
Press PAUSE (Write) button.
19
Wait for 1 seconds.
20
6
01
27
Press PAUSE (Write) button.
21
6
02
Check the data changes to
“01”.
22
6
0C
Check the data is “00”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
64
00
3
6
4D
00
4
6
40
00
5
0
10
07
6
E
10
Set the bit value of bit1 is “1”,
(7E)
and press PAUSE (Write)
button. (Note 7)
7
0
10
00
8
6
61
00
9
Wait for 3 seconds.
10
0
10
09
11
F
4A
00
(9F)
12
F
4B
00
(9F)
13
0
10
00
14
6
01
25
Press PAUSE (Write) button.
15
6
02
Check the data changes to
“01”.
16
6
01
00
Press PAUSE (Write) button.
17
BF
19
AB
18
BF
90
40
19
0
01
00
Page 6-14
Summary of Contents for DSR-PD198P
Page 445: ......