6-25
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
3.
PSD Sensor Gradient Adjustment (VC-543 board)
Input average offset voltage of the YAW (SE8502)/PITCH
(SE8501) sensors on GY-014 board.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
7F
Adjustment Address
00 to 1F
Specified value
Data of page: 72, address: 02 is “01”
Note 1:
Set the camera on a horizontal table.
Note 2:
Check that the data of page: 72, address: 02 is “00”
If not, select page: 72, address: 01, set data: 00, and press
the PAUSE (Write) button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
7
3
2
01
97
Press PAUSE (Write) button.
(72)
(Note 3)
4
Wait for 6 seconds.
5
2
02
Check the data changes to
(72)
“01”. (Note 4)
6
F
16
Check the data changes to
(7F)
“11”.
7
2
01
00
Press PAUSE (Write) button.
(72)
8
0
10
00
9
0
01
00
Note 3:
The adjustment data will be automatically input to page:
7F, address: 00 to 1F.
Note 4:
If the data is other than “01”, adjustment has errors.
Contents of error is written into page: 7, address: 02. See
the following table.
Data of page: 7F,
Error contents
address: 16
X, Y = 0
In the middle of adjustment
X, Y = 2
Abnormal termination
X, Y = 1
Normal termination
RadarW
RadarW
RadarW
4.
Lens Adjustment
The inner focus lens MR adjustment is carried out automatically.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
30, 40 to 4F
Specified value
Data of page: 6, address: 0C is “00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment ” after this adjustment.
Note 3:
If reading/writing data on page 6F, set data: 06 to page:
0, address: 10, and then select page F. By this data set-
ting, the page 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 4)
3
6
01
BD
Press PAUSE (Write) button.
(Note 5)
4
6
02
Check the data changes to “01”.
5
6
0C
Check the data is “00”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 30, 40 to 4F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
0
01
00
“X, Y”: X: High 4 bits (Yaw sensor)
Y: Low 4 bits (Pitch sensor)
RadarW
RadarW
RadarW
Summary of Contents for DSR-PD198P