6-11
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Order Page Address Data
Procedure
Check the data changes to
8
3
90
“1C”.
9
Perform “Modification of 8,
9, C, 13, 18, 1C, 1D, 1E Page
Data”
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
2.
Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data
If the 8, 9, C, 13, 18, 1C, 1D, 1E page data has been initialized,
change the data of the “Fixed data-2” address shown in the fol-
lowing table by manual input.
Processing before Modification 8, 9, C, 13, 18, 1C, 1D, 1E
page data:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
71
01
Press PAUSE (Write) button.
Modifying Method:
1) If modification of data on pages 8, 9, C, set data: 00 to page: 0,
address: 10, and then select pages 8, 9, C.
2) If modification of data on pages 13, 18, 1C, 1D, 1E, set data:
01 to page: 0, address: 10, and then select pages 3, 8, C, D, E.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the cam-
corder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 8, 9, C, 13, 18, 1C,
1D, 1E page data:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
70
10
Press PAUSE (Write) button.
4
3
70
Check the data changes to
“11”.
5
2
00
29
6
2
01
29
Press PAUSE (Write) button.
4.
9 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
3.
8 Page table
Note 1:
Check that the data of page: 0, address: 10 is“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to F1
Fixed data-1 (Initialized data)
F2
Fixed data-2
F3 to FF
Fixed data-1 (Initialized data)
Summary of Contents for DSR-PD198P